found on smartmontools-support.
smartctl version 5.33 [i386-pc-mingw32] Copyright (C) 2002-4 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD2500AB-00DYA0
Serial Number:    WD-WMAEH1676221
Firmware Version: 15.05R15
User Capacity:    250,059,350,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   6
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Thu Nov 11 13:38:27 2004 GMT Standard Time
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                        was aborted by an interrupting command 
from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 121) The previous self-test completed having
                                        the read element of the test failed.
Total time to complete Offline 
data collection:                 (7590) seconds.
Offline data collection
capabilities:                    (0x79) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  95) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   200   152   051    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0007   127   123   021    Pre-fail  Always       
-       4191
  4 Start_Stop_Count        0x0032   100   100   040    Old_age   Always       
-       50
  5 Reallocated_Sector_Ct   0x0033   193   193   140    Pre-fail  Always       
-       111
  7 Seek_Error_Rate         0x000b   200   200   051    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   091   091   000    Old_age   Always       
-       6794
 10 Spin_Retry_Count        0x0013   100   253   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0013   100   253   051    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       50
194 Temperature_Celsius     0x0022   115   253   000    Old_age   Always       
-       35
196 Reallocated_Event_Count 0x0032   141   141   000    Old_age   Always       
-       59
197 Current_Pending_Sector  0x0012   176   176   000    Old_age   Always       
-       996
198 Offline_Uncorrectable   0x0012   197   161   000    Old_age   Always       
-       139
199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0009   145   155   051    Pre-fail  Offline      
-       1843

SMART Error Log Version: 1
ATA Error Count: 101 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 101 occurred at disk power-on lifetime: 945 hours (39 days + 9 hours)
  When the command that caused the error occurred, the device was doing SMART 
Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 03 9d 12 e0  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  00 00 25 00 00 08 00 00  44d+06:27:36.700  NOP [Abort queued commands]
  1c 00 12 00 00 0b 9d 00  44d+06:27:36.700  RECALIBRATE [RET-4]
  00 00 e7 00 00 00 00 00  44d+06:27:36.700  NOP [Abort queued commands]
  00 00 26 00 00 59 34 00  44d+06:27:36.700  NOP [Abort queued commands]
  00 00 25 00 00 03 00 00  44d+06:27:36.700  NOP [Abort queued commands]

Error 100 occurred at disk power-on lifetime: 945 hours (39 days + 9 hours)
  When the command that caused the error occurred, the device was doing SMART 
Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 08 03 9d 12 e0  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  00 00 25 00 00 08 00 00  44d+06:27:34.800  NOP [Abort queued commands]
  00 00 e7 00 00 00 00 00  44d+06:27:34.800  NOP [Abort queued commands]
  00 00 26 00 00 59 34 00  44d+06:27:34.800  NOP [Abort queued commands]
  00 00 25 00 00 03 00 00  44d+06:27:34.800  NOP [Abort queued commands]
  1c 00 12 00 00 03 9d 00  44d+06:27:34.800  RECALIBRATE [RET-4]

Error 99 occurred at disk power-on lifetime: 945 hours (39 days + 9 hours)
  When the command that caused the error occurred, the device was doing SMART 
Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 28 03 9d 12 e0  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  00 00 25 00 00 28 00 00  44d+06:27:27.000  NOP [Abort queued commands]
  00 00 00 00 00 00 00 00  44d+06:27:27.000  NOP [Abort queued commands]
  00 00 e7 00 00 00 00 00  44d+06:27:27.000  NOP [Abort queued commands]
  00 00 65 00 00 93 a9 00  44d+06:27:27.000  NOP [Abort queued commands]
  00 00 25 00 00 2b 00 00  44d+06:27:27.000  NOP [Abort queued commands]

Error 98 occurred at disk power-on lifetime: 945 hours (39 days + 9 hours)
  When the command that caused the error occurred, the device was doing SMART 
Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 28 03 9d 12 e0  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  00 00 25 00 00 28 00 00  44d+06:27:25.050  NOP [Abort queued commands]
  00 00 00 00 00 00 00 00  44d+06:27:25.050  NOP [Abort queued commands]
  00 00 e7 00 00 00 00 00  44d+06:27:25.050  NOP [Abort queued commands]
  00 00 25 00 00 2b 00 00  44d+06:27:25.050  NOP [Abort queued commands]
  00 00 00 00 00 00 00 00  44d+06:27:25.050  NOP [Abort queued commands]

Error 97 occurred at disk power-on lifetime: 945 hours (39 days + 9 hours)
  When the command that caused the error occurred, the device was doing SMART 
Offline or Self-test.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 2b 03 9d 12 e0  Error: 

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  00 00 25 00 00 2b 00 00  44d+06:27:19.250  NOP [Abort queued commands]
  00 00 00 00 00 00 00 00  44d+06:27:19.250  NOP [Abort queued commands]
  00 00 e7 00 00 00 00 00  44d+06:27:19.250  NOP [Abort queued commands]
  1c 00 12 00 00 00 9d 00  44d+06:27:19.250  RECALIBRATE [RET-4]
  00 00 35 00 00 08 00 00  44d+06:27:19.250  NOP [Abort queued commands]

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed: read failure       90%       241         
470981891

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to