Hi,
I can see OCZ Trion 100[1] is missing in the database. Here comes drive info
and a tentative patch. Attribute names in the patch come from OCZ's SSD Guru
tool. I'd be glad to see the drive supported by smartmontools.
Libor
[1]
http://ocz.com/consumer/company/newsroom/press/ocz-releases-value-oriented-trion-100-ssd-series-with-premium-toshiba-tlc-nand-flash
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: OCZ-TRION100
Device Model: OCZ-TRION100
Serial Number: 555B60AOKMBX
LU WWN Device Id: 5 e83a97 20022e96c
Firmware Version: SAFM11.1
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Aug 13 21:33:50 2015 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 30) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 2) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
9 Power_On_Hours -O--C- 100 100 000 - 7
12 Power_Cycle_Count -O--C- 100 100 000 - 8
167 SSD_Protect_Mode -O---K 100 100 000 - 0
168 SATA_PHY_Error_Count -O--C- 100 100 000 - 0
169 Total_Bad_Block_Count PO---- 100 100 010 - 0
173 Erase_Count -O--C- 200 200 000 - 0
192 Power-Off_Retract_Count -O--C- 100 100 000 - 4
194 Temperature_Celsius PO---K 060 041 030 - 40 (Min/Max 24/59)
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 7 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 2) ==
1 0x008 4 8 Lifetime Power-On Resets
1 0x010 4 7 Power-on Hours
1 0x018 6 201301304 Logical Sectors Written
1 0x020 6 269297 Number of Write Commands
1 0x028 6 125534326 Logical Sectors Read
1 0x030 6 4725345 Number of Read Commands
1 0x038 6 25742755 Date and Time TimeStamp
4 ===== = = == General Errors Statistics (rev 1) ==
4 0x008 4 0 Number of Reported Uncorrectable Errors
4 0x010 4 0 Resets Between Cmd Acceptance and Completion
5 ===== = = == Temperature Statistics (rev 1) ==
5 0x008 1 32 Current Temperature
5 0x010 1 32 Average Short Term Temperature
5 0x018 1 32 Average Long Term Temperature
5 0x020 1 50 Highest Temperature
5 0x028 1 5 Lowest Temperature
5 0x030 1 50 Highest Average Short Term Temperature
5 0x038 1 16 Lowest Average Short Term Temperature
5 0x040 1 50 Highest Average Long Term Temperature
5 0x048 1 16 Lowest Average Long Term Temperature
5 0x050 4 0 Time in Over-Temperature
5 0x058 1 50 Specified Maximum Operating Temperature
5 0x060 4 0 Time in Under-Temperature
5 0x068 1 5 Specified Minimum Operating Temperature
6 ===== = = == Transport Statistics (rev 1) ==
6 0x008 4 5 Number of Hardware Resets
6 0x018 4 0 Number of Interface CRC Errors
7 ===== = = == Solid State Device Statistics (rev 1) ==
7 0x008 1 0 Percentage Used Endurance Indicator
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 12 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
--- /var/lib/smartmontools/drivedb/drivedb.h.orig 2015-08-13 21:10:58.918655953 +0200
+++ /var/lib/smartmontools/drivedb/drivedb.h 2015-08-13 21:18:49.882678575 +0200
@@ -545,6 +545,14 @@
"-v 249,raw48,Total_NAND_Prog_Ct_GiB "
"-v 251,raw48,Total_NAND_Read_Ct_GiB"
},
+ { "OCZ-TRION100",
+ "OCZ-TRION100",
+ "", "",
+ "-v 167,raw48,SSD_Protect_Mode "
+ "-v 168,raw48,SATA_PHY_Error_Count "
+ "-v 169,raw48,Total_Bad_Block_Count "
+ "-v 173,raw48,Erase_Count "
+ },
{ "InnoDisk InnoLite SATADOM D150QV-L SSDs", // tested with InnoLite SATADOM D150QV-L/120319
"InnoLite SATADOM D150QV-L",
"", "",
------------------------------------------------------------------------------
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database