LOL!

Yes, it's reasonable.

The HUAWEI handler also "resets" the modem, which takes time (see  
http://smslib.googlecode.com/svn/smslib/trunk/src/java/org/smslib/modem/athandler/ATHandler_Huawei.java,
 
method init(), CFUN call).

The default handler does not.

I guess, the mistery is solved :)

On Tuesday, June 5, 2012 11:45:18 PM UTC+3, Juan Bressan wrote:
>
> @ T.Delenikas:
> *
> *
> Hey Thanasis!
>
> Finally found the problem, is this a bug? I found that initializing my 
> modem as follows:
>
> SerialModemGateway("modem.com4", "COM16", 57600, "Huawei", "E160");
>
> takes x3times what it takes if I do it without specifying "Huawei" in the 
> manufacturer string, just passed an emtpy string or whatever. Is there any 
> specific initialization done when specifying this string? Kinda weird.
>
> Let me know bc now I'm pretty curious about it :)
>

-- 