On 01/25/2011 04:14 PM, uprinz wrote: > I think it is because the i.MX25 version of this stack is not fully > implemented. > The output of the above command is exactly like the one from the > documentation. I.e. it includes the restart-ms token too but using it > results in the following return: > > # ip link set can0 type can restart-ms 20000 > RTNETLINK answers: Operation not supported > > So there are basic functions missing I guess.
Use the mainline flexcan driver, it works on mx25, mx28 and mx35 regards, Marc -- Pengutronix e.K. | Marc Kleine-Budde | Industrial Linux Solutions | Phone: +49-231-2826-924 | Vertretung West/Dortmund | Fax: +49-5121-206917-5555 | Amtsgericht Hildesheim, HRA 2686 | http://www.pengutronix.de |
signature.asc
Description: OpenPGP digital signature
_______________________________________________ Socketcan-users mailing list [email protected] https://lists.berlios.de/mailman/listinfo/socketcan-users