> I tried whatever kind of trick. the un-pair, pair trick works for me. make sure you have the latest BT chip drivers too.
> I have no problem at all with Shearwater Cloud and that’s strange. The Shearwater Cloud is using a different Windows backend called Windows RT. Subsurface is using the native Windows backend. There is no way for us to fix that unless we re-write Subsurface as a Universal Windows Platform app in C#, which is no-go. Windows 10 needs to sort their flakiness for some chipsets on the native backend. For instance the OSTC+ with latest Windows 10, connected fine each time and does not need the un-pair, pair trick. lubomir -- On Sat, 9 Nov 2019 at 17:28, tormento <turm...@gmail.com> wrote: > > I tried whatever kind of trick. > > I have no problem at all with Shearwater Cloud and that’s strange. > > If a Windows issue, how can it be solved or worked around? > > Alberto > > P.S I’d like to know if other Perdix have same issues. > > Il giorno sab 9 nov 2019 alle 15:12 Lubomir I. Ivanov <neolit...@gmail.com> > ha scritto: >> >> on Windows, try unpairing and pairing the Perdix before each downlioad >> from Subsurface. >> the status of the device in the Control Panel should turn from Paired >> to Connected if successful. >> please note, this is a Windows issue and not a Subsurface issue. >> >> lubomir >> -- >> >> On Mon, 4 Nov 2019 at 11:28, tormento <turm...@gmail.com> wrote: >> > >> > Ok, I tried to download dive on another laptop with integrated BT with or >> > without dongle and don't work there too. >> > >> > In the meantime I have done it with newest Testflight build on iOS but I'd >> > like to be able to download from Windows version too. >> > >> > Alberto >> > >> > Il giorno sab 2 nov 2019 alle ore 07:48 Jef Driesen >> > <j...@libdivecomputer.org> ha scritto: >> >> >> >> On 2/11/19 07:41, tormento wrote: >> >> > I am getting errors while importing dives from Perdix AI with its BT >> >> > dongle (I >> >> > don't hava any other to try) while it's own software can import dives >> >> > correctly. >> >> > >> >> > I select choose Bluetooth mode, find the Perdix and save. >> >> > >> >> > When I try to import, I get: >> >> > >> >> > Connecting to BLE device >> >> > Connecting >> >> > >> >> > Then a error windows pops up with "Dive data import error". >> >> > >> >> > image.png >> >> > >> >> > The log tells: >> >> > >> >> > Subsurface: v4.9.3-242-g9c8fbe494db2, built with libdivecomputer >> >> > v0.7.0-devel-Subsurface-NG (426a39fc7378cac3f5b1d3983be38d56ab526e78) >> >> > INFO: Open: transport=32 >> >> > INFO: Configure: baudrate=115200, databits=8, parity=0, stopbits=0, >> >> > flowcontrol=0 >> >> > INFO: Timeout: value=3000 >> >> > INFO: Sleep: value=300 >> >> > INFO: Purge: direction=3 >> >> > INFO: Write: size=11, data=0100FF0105002E902000C0 >> >> > >> >> > No .bin is generated. >> >> >> >> Uncheck the "Save libdivecomputer dumpfile" checkbox. The Shearwater >> >> Perdix AI >> >> communication protocol doesn't support memory dumps. Trying to download a >> >> memory >> >> dump will always fail with DC_STATUS_UNSUPPORTED. >> >> >> >> For the diagnostics purposes, the log file is sufficient for these models. >> >> >> >> Jef >> > >> > _______________________________________________ >> > subsurface mailing list >> > subsurface@subsurface-divelog.org >> > http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface > > _______________________________________________ > subsurface mailing list > subsurface@subsurface-divelog.org > http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface _______________________________________________ subsurface mailing list subsurface@subsurface-divelog.org http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface