[email protected] said: > Regarding the earlier comment about your battery charge level not > changing... Is this still true?
Just checked again and found that the charge level is updated now, but only every 30s. (The code in acpibat_refresh() suggests that cached values are kept only for 5s, and I believe that is how it did behave formerly.) I definitely watched the battery state for a couple of minutes yesterday, so something else must have happened. Looking at acpibat_refresh()... the 5-seconds check uses microtime() which is not necessarily monotonic. And, iirc, I had booted Windows before, which sets the RTC to GMT+1, so I had to force the clock back by a manual "ntpdate". This might have killed status updating. Well, just a hypothesis, but I'd suggest to use getmicrouptime() for these checks. best regards Matthias ------------------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------------------ Forschungszentrum Juelich GmbH 52425 Juelich Sitz der Gesellschaft: Juelich Eingetragen im Handelsregister des Amtsgerichts Dueren Nr. HR B 3498 Vorsitzende des Aufsichtsrats: MinDir'in Baerbel Brumme-Bothe Geschaeftsfuehrung: Prof. Dr. Achim Bachem (Vorsitzender), Dr. Ulrich Krafft (stellv. Vorsitzender), Prof. Dr.-Ing. Harald Bolt, Prof. Dr. Sebastian M. Schmidt ------------------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------------------