Interesting this third overtone/fundamental*3 idea but what makes the third overtone not equal to the fundamental*3? Is the crystal operated in series or parallel resonance?
On Thu, Aug 30, 2012 at 10:30 PM, Magnus Danielson < mag...@rubidium.dyndns.org> wrote: > On 08/30/2012 06:33 PM, Bob Camp wrote: > >> Hi >> >> The fundamental / third approach is one of several possible ways to go. >> You >> can also run an SC on the B and C modes to get thermometer data. Early >> implementations used a pair of independent blanks, one cut to be a good >> thermometer. Some have even gone as far as to mount a thermistor on the >> crystal. >> >> No matter what you do, it adds cost. >> > > The reason for doing it is to lower powerconsumption in critical > applications. > > Cheers, > Magnus > > > _______________________________________________ > time-nuts mailing list -- time-nuts@febo.com > To unsubscribe, go to > https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. > _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.