was messing around with one of theocxo's last night. The most easily way to 
guarantee an instantincorrect frequency turn on is to either start it at an 
under voltagecondition(ex. initial power on at 10V, with full current), or 
tostart it with a current limited power supply, that delivers half themax 
instant turn on current(ex. giving it a 500mA limit, when it cantake 1A). 
Interestingly enough I have cases of the cfp oscillators,and 3 stp variants. I 
have been able to test all of the stp's andthey exhibit this bug. Those were 
from CIC GGER gpsdo's, that is whatI learned many many years ago. My CFP's are 
all unused, still intheir original shipping boxes. The unfortunate thing about 
that isthe product label information has been covered up. With the 4 cases 
Ihave almost all are in sequential order SN wise.
Sorryfor the long post.
Thanks,
Brendan