On 8/31/16 12:01 PM, Mark Sims wrote:
You have to be careful choosing a linear regulator to clean up a switching
supply. Many just wind up passing the noise through. Pay attention to the
noise, PSRR and CMRR vs frequency specs, etc
Indeed..
a lot of monolithic regulators have a remarkably low cutoff frequency.
On the other hand, the LT3042 has 80 dB PSRR up to a few MHz. 55dB at
10 MHz.
Take a look at the "voltage regulation" section of that home built VNA page for
an example:
http://hforsten.com/cheap-homemade-30-mhz-6-ghz-vector-network-analyzer.html
_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.
_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.