There's an excellent article out there on the web called "Low Voltage, the 
incompetent ignition source"  I highly recommend a read. 
I dealt with a case like this a couple years ago.  Failed fet in an H bridge 
caused a fault which the brick SMPS picked up as a short, and went into 
"hiccup" mode on.
The energy delivered in "hiccup" mode was about 1W average, and that was 
enough, after several hours, to cause ignition and sustained flame on the PCB.