> My intention is to leave the instrument on for severalweeks in order to see > if it is stable. Right nowmy concern is wether the 2nd harmonic > readingindicates a wear out of the photo cell. > When repairing the RFV Cavity, all components weretaken out and carefully > examined. There wereno dimmed or darkened glass surfaces > whatsoever.Apart from repairing the TX heater, the only other thingwas > replacing the 1K something resistor in the TXassembly.
You've checked the ESR of all the axial electrolytic caps, right? If not, it's quite unlikely that they're all good. -- john, KE5FX Miles Design LLC _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.