Sure they are: SensirionSht11C. However I have no idea how to turn them on/off. This might not even be necessary (e.g. they would be turned on automatically for a single sampling interval)?
Cheers, Urs Oussama Chougna schrieb: > The Humidity and Temperature sensors are not implemented in TinyOS 2. > > There is a DemoSensorC component but it measures the internal voltage. > > http://www.tinyos.net/tinyos-2.x/doc/html/nesdoc/telosb/ > > > But if you know the ADC port settings, you can write your own > implementation. > > > Good luck, > > Oussama > > > > -----Original Message----- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] On Behalf Of Tiago > Camilo > Sent: dinsdag 26 juni 2007 14:45 > To: tinyos-help@Millennium.Berkeley.EDU; [EMAIL PROTECTED] > Subject: [Tinyos-help] From Boomerang to TinyOS2.x,sensor interactivity > (ON/OFF) > > Hi all, > > I am trying to migrate my tmotes from Boomerang to TinyOS 2.0.1... > > Till now i am following the tinyos2.x tutorial with no problems, but now > in lesson 5, my first issue had arrived. > > In Boomerang i had the possibility to turn on/off the Temperature and > Humidity sensors by calling: > > >call HumidityControl.init(); > >call HumidityControl.stop(); > > My question is: is there any kind of similar procedures that i can call >>from TinyOS2.x? The same question rises for the events: > HumidityError.error() and TemperatureError.error(). > > Thanks in advance, > Tiago Camilo _______________________________________________ Tinyos-help mailing list Tinyos-help@Millennium.Berkeley.EDU https://mail.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help