This adds a member to TMU FDT node for providing hardware
tripping temperature threshold.

Signed-off-by: Akshay Saraswat <aksha...@samsung.com>
Acked-by: Simon Glass <s...@chromium.org>
---
Changes since v10:
        - None.

 board/samsung/dts/exynos5250-smdk5250.dts | 1 +
 doc/device-tree-bindings/exynos/tmu.txt   | 5 ++++-
 2 files changed, 5 insertions(+), 1 deletion(-)

diff --git a/board/samsung/dts/exynos5250-smdk5250.dts 
b/board/samsung/dts/exynos5250-smdk5250.dts
index 00dac40..1c2d52d 100644
--- a/board/samsung/dts/exynos5250-smdk5250.dts
+++ b/board/samsung/dts/exynos5250-smdk5250.dts
@@ -72,6 +72,7 @@
                samsung,max-temp        = <125>;
                samsung,start-warning   = <95>;
                samsung,start-tripping  = <105>;
+               samsung,hw-tripping     = <110>;
                samsung,efuse-min-value = <40>;
                samsung,efuse-value     = <55>;
                samsung,efuse-max-value = <100>;
diff --git a/doc/device-tree-bindings/exynos/tmu.txt 
b/doc/device-tree-bindings/exynos/tmu.txt
index bb734dc..89d3bf0 100644
--- a/doc/device-tree-bindings/exynos/tmu.txt
+++ b/doc/device-tree-bindings/exynos/tmu.txt
@@ -8,7 +8,9 @@ Required properties:
  - samsung,max-temp : Maximum temperature value (125 degree celsius)
        - Current temperature of SoC should be less than this value.
  - samsung,start-warning : Temperature at which TMU starts giving warning 
(degree celsius)
- - samsung,start-tripping : Temperature at which system will trip and shutdown 
(degree celsius)
+ - samsung,start-tripping : Temperature at which TMU shuts down the system 
(degree celsius)
+ - samsung,hw-tripping : Temperature at which hardware tripping should happen
+       in case TMU fails to power off (degree celsius)
  - samsung,efuse-min-value : SOC efuse min value (Constant 40)
        - efuse-value should be more than this value.
  - samsung,efuse-value : SOC actual efuse value (Literal value)
@@ -33,6 +35,7 @@ tmu@10060000 {
        samsung,max-temp = <125>;
        samsung,start-warning = <95>;
        samsung,start-tripping = <105>;
+       samsung,hw-tripping = <110>;
        samsung,efuse-min-value = <40>;
        samsung,efuse-value = <55>;
        samsung,efuse-max-value = <100>;
-- 
1.8.0