Hi, On Thu, May 30, 2013 at 7:19 PM, Jagannadha Sutradharudu Teki <jagannadha.sutradharudu-t...@xilinx.com> wrote: > Use the exact names for W25Q 0x40XX ID's flash parts, as the same > sizes of flashes comes with different ID's. so-that the distinguishes > becomes easy with this change. > > Signed-off-by: Jagannadha Sutradharudu Teki <jaga...@xilinx.com> > --- > Changes for v2: > - none > > drivers/mtd/spi/winbond.c | 10 +++++----- > 1 file changed, 5 insertions(+), 5 deletions(-) > > diff --git a/drivers/mtd/spi/winbond.c b/drivers/mtd/spi/winbond.c > index 8457808..3c0ca88 100644 > --- a/drivers/mtd/spi/winbond.c > +++ b/drivers/mtd/spi/winbond.c > @@ -55,27 +55,27 @@ static const struct winbond_spi_flash_params > winbond_spi_flash_table[] = { > { > .id = 0x4014, > .nr_blocks = 16, > - .name = "W25Q80BL", > + .name = "W25Q80BL/W25Q80BV", > }, > { > .id = 0x4015, > .nr_blocks = 32, > - .name = "W25Q16", > + .name = "W25Q16CL/W25Q16DV",
The id codes were same for these two parts, I think there is no way to detect the separately. Any idea? Thanks, Jagan. > }, > { > .id = 0x4016, > .nr_blocks = 64, > - .name = "W25Q32", > + .name = "W25Q32BV", > }, > { > .id = 0x4017, > .nr_blocks = 128, > - .name = "W25Q64", > + .name = "W25Q64CV", > }, > { > .id = 0x4018, > .nr_blocks = 256, > - .name = "W25Q128", > + .name = "W25Q128BV", > }, > { > .id = 0x4019, > -- > 1.8.3 > > _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot