On Sun, 2015-01-04 at 21:05 +0100, Hans de Goede wrote: > Hitachi tx18d42vm LCD panels have an onboard controller which needs some > initialization via spi for the panel to become functional as a regular LVDS > panel.
This doesn't sound terribly sunxi specific, shouldn't sunxi_lcd_panel_hitachi_tx18d42vm_init be generic but making use of some sort of arch-provided interface for actually talking SPI to the device (which may or may not use the generic SPI infra, as your code comment talked about)? Ian. _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot