On Monday 27 July 2009 18:40:31 Alessandro Rubini wrote: > The entry point of an image can be 0 (like on PowerPC), so allow next_out > to be NULL in inflate() > > Signed-off-by: Alessandro Rubini <rub...@unipv.it> > --- > > Stefan Roese: > > I'll try to uncompress to something != 0 tomorrow on PPC. > > You are right. I naively thought my arm has RAM at 0 like PPC, but > entry point of image is not really 0.
Yes, this works: Tested-by: Stefan Roese <s...@denx.de> Thanks. Best regards, Stefan ===================================================================== DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: off...@denx.de ===================================================================== _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot