On 24/01/20 10:14 AM, Marek Vasut wrote:
> The timeout parameter of omap3_wdt_start() is in miliseconds, while
> GET_WLDR_VAL() expects parameter in seconds. Fix this so the WDT
> driver is actually usable.
> 
> Signed-off-by: Marek Vasut <ma...@denx.de>
> Cc: Grygorii Strashko <grygorii.stras...@ti.com>
> Cc: Sam Protsenko <semen.protse...@linaro.org>
> Cc: Suniel Mahesh <suni...@techveda.org>

Reviewed-by: Lokesh Vutla <lokeshvu...@ti.com>

A cover letter would really be nice to get a brief on the series.

Thanks and regards,
Lokesh

Reply via email to