On 24/01/20 10:14 AM, Marek Vasut wrote: > The timeout parameter of omap3_wdt_start() is in miliseconds, while > GET_WLDR_VAL() expects parameter in seconds. Fix this so the WDT > driver is actually usable. > > Signed-off-by: Marek Vasut <ma...@denx.de> > Cc: Grygorii Strashko <grygorii.stras...@ti.com> > Cc: Sam Protsenko <semen.protse...@linaro.org> > Cc: Suniel Mahesh <suni...@techveda.org> Series pulled into u-boot-ti tree. Thanks and regards, Lokesh
- [PATCH 1/3] watchdog: omap_wdt: Fix WDT timeout configuration Marek Vasut
- [PATCH 2/3] watchdog: omap_wdt: Fix WDT reloading Marek Vasut
- [PATCH 3/3] watchdog: omap_wdt: Fix WDT coding style Marek Vasut
- Re: [PATCH 1/3] watchdog: omap_wdt: Fix WDT timeout conf... Lokesh Vutla
- Re: [PATCH 1/3] watchdog: omap_wdt: Fix WDT timeout conf... Lokesh Vutla