On 3/11/22 19:14, Robert Marko wrote:
Generic SDHCI driver received support for checking the busy status by
polling the DAT[0] level instead of waiting for the worst MMC switch time.

Unfortunately, it appears that this does not work for Xenon controllers
despite being a part of the standard SDHCI registers and the Armada 3720
datasheet itself telling that BIT(20) is useful for detecting the DAT[0]
busy signal.

I have tried increasing the timeout value, but I have newer managed to
catch DAT_LEVEL bits change from 0 at all.

This issue appears to hit most if not all SoC-s supported by Xenon driver,
at least A3720, A8040 and CN9130 have non working eMMC currently.

So, until a better solution is found drop the wait_dat0 OP for Xenon.
I was able to only test it on A3720, but it should work for others as well.

Fixes: 40e6f52454fc ("drivers: mmc: Add wait_dat0 support for sdhci driver")
Signed-off-by: Robert Marko <robert.ma...@sartura.hr>

Reviewed-by: Stefan Roese <s...@denx.de>

Thanks,
Stefan

---
  drivers/mmc/xenon_sdhci.c | 7 ++++++-
  1 file changed, 6 insertions(+), 1 deletion(-)

diff --git a/drivers/mmc/xenon_sdhci.c b/drivers/mmc/xenon_sdhci.c
index e292f2903d..2f8805096c 100644
--- a/drivers/mmc/xenon_sdhci.c
+++ b/drivers/mmc/xenon_sdhci.c
@@ -439,6 +439,8 @@ static const struct sdhci_ops xenon_sdhci_ops = {
        .set_ios_post = xenon_sdhci_set_ios_post
  };
+static struct dm_mmc_ops xenon_mmc_ops;
+
  static int xenon_sdhci_probe(struct udevice *dev)
  {
        struct xenon_sdhci_plat *plat = dev_get_plat(dev);
@@ -452,6 +454,9 @@ static int xenon_sdhci_probe(struct udevice *dev)
        host->mmc->dev = dev;
        upriv->mmc = host->mmc;
+ xenon_mmc_ops = sdhci_ops;
+       xenon_mmc_ops.wait_dat0 = NULL;
+
        /* Set quirks */
        host->quirks = SDHCI_QUIRK_WAIT_SEND_CMD | SDHCI_QUIRK_32BIT_DMA_ADDR;
@@ -568,7 +573,7 @@ U_BOOT_DRIVER(xenon_sdhci_drv) = {
        .id             = UCLASS_MMC,
        .of_match       = xenon_sdhci_ids,
        .of_to_plat = xenon_sdhci_of_to_plat,
-       .ops            = &sdhci_ops,
+       .ops            = &xenon_mmc_ops,
        .bind           = xenon_sdhci_bind,
        .probe          = xenon_sdhci_probe,
        .remove         = xenon_sdhci_remove,

Viele Grüße,
Stefan Roese

--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de

Reply via email to