On 03.02.23 19:51, Tom Rini wrote: > On Fri, Feb 03, 2023 at 01:26:37PM +0100, Jan Kiszka wrote: > >> From: Jan Kiszka <jan.kis...@siemens.com> >> >> There are many ways to get a signed firmware for the IOT2050 devices, >> namely for the parts under user-control. This script documents one way >> of doing it, given a signing key. Augment the board documentation with >> the required procedure around it. >> >> Signed-off-by: Jan Kiszka <jan.kis...@siemens.com> > [snip] >> +# currently broken in upstream >> +#source/tools/binman/binman replace -i flash.bin -f f...@0x380000.fit >> fit@0x380000 >> +dd if=f...@0x380000.fit of=flash.bin bs=$((0x1000)) >> seek=$((0x380000/0x1000)) conv=notrunc > > Is that still a true comment? >
binman: Node '/fit@0x380000/images/u-boot': Offset 0x0 (0) size 0xb8870 (755824) is outside the section '/fit@0x380000' starting at 0x0 (0) of size 0x400 (1024) And for the second call: binman: Node '/fit@0x380000': Replacing sections is not implemented yet We tried fixing but eventually had to give up. binman is not easy to understand in these corners. Jan -- Siemens AG, Technology Competence Center Embedded Linux