Kevin, If what you are asking is 'when is the latest version of a program is executed in UD?', my answer is immediately.
The caveat is an older version seems to execute until the process that has been executing it expires or goes to ECL. If a program is executed in our menu system, the only way to reliably execute the latest version is exit & re-enter the menu. If a program is executed by a phantom, the only way to reliably execute the latest version is to stop & re-start the phantom. If a program has been executed by a uniobjects slave process, only slave processes started after the latest version is catalogued are executing it. If I knew how to apply the 'NEWPCODE' command, maybe the stop/starts would not be necessary. TomC -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Kevin King Sent: Monday, August 07, 2006 7:04 PM To: u2-users@listserver.u2ug.org Subject: [U2] RE: [UD] Program Cache Expiration - RESTATED Does anyone know offhand how long a catalogued program will stay in cache before it's expired and a new version loaded with Unidata? -Kevin [EMAIL PROTECTED] http://www.PrecisOnline.com ** Check out scheduled Connect! training courses at http://www.PrecisOnline.com/train.html. ------- u2-users mailing list u2-users@listserver.u2ug.org To unsubscribe please visit http://listserver.u2ug.org/ ------- u2-users mailing list u2-users@listserver.u2ug.org To unsubscribe please visit http://listserver.u2ug.org/