Hi, There is a note from IBM on this: 119628. It mentions that we can't inquire as to the value of SYSTEM(1999) to know if it has been turned off or not as it will always report zero. So it looks like we will have to turn it off to make sure. It may explain some anomalies.
I previously thought it was turned off because I had done a small program that would do this: CRT SYSTEM(1999) and it would print zero. ----- Original Message ---- From: Martin Phillips <martinphill...@ladybridge.com> To: u2-users@listserver.u2ug.org Sent: Friday, March 20, 2009 6:09:46 PM Subject: Re: [U2] [UV] Config parameter for the READU Hi Jacques, > If the value of SYSTEM(1999) is set to zero does that mean > that this featured is turned off and that the READU will wait > however long it takes to get the lock or does it mean it is set > to the default 3600 waiting value ? Setting it to zero disables it completely. To my mind, this is the only sensible way to run but I'm open to arguments. Martin Phillips Ladybridge Systems Ltd 17b Coldstream Lane, Hardingstone, Northampton, NN4 6DB +44-(0)1604-709200 ------- u2-users mailing list u2-users@listserver.u2ug.org To unsubscribe please visit http://listserver.u2ug.org/ ------- u2-users mailing list u2-users@listserver.u2ug.org To unsubscribe please visit http://listserver.u2ug.org/