David:
Have you turned on UniObjects error logging? If not, create the
following item in the UDTHOME directory:
serverdebug
001 udcs 10 E:\U2\ud\log\udcs\udcs.log
My UDTHOME is located at "E:\U2\ud" so your path should replace mine
from above. Also, I've created a "udcs" subdirectory under the UDTHOME
"log" subdirectory. You can actually just name (and place) this log
file whatever and wherever you like. After each UO connection there's a
bunch of stuff in it that most often helps me.
HTH,
Bill
Untitled Page
- - -
*/Fav Icon Advantos Systems, Inc./*
☎ Tel: 760-944-5570 x7002 | ☏ Fax: 760-655-1583
"The Property Management Advantage."
----- Original Message -----
*From:* dgr...@dagconsulting.com
*To:* 'U2 Users List' <u2-users@listserver.u2ug.org>
*Date:* 3/22/2013 1:43 PM
*Subject:* [U2] REDBACK Fatal UniBasic errors
I'm accessing UniData via .NET and Redback. But if there is a fatal
UniBasic error, like trying to access an unopened file, I get the following:
dagLink.DOAdoExecute - ADO Record Set Execute - Connection to Application
Server lost
Responder Error: (errno=32 The process cannot access the file because it is
being used by another process.)
Responder Error: (errno=32 The process cannot access the file because it is
being used by another process.)
Responder Error:
**** Server Err: ****
SpGetLen error, rc=-109
**** Output Log: ****
none.
**** Error Log: ****
none.
*********************
It then goes on to tell me that we have a Responder Error.
The rgw.log has this:
102340,RESP,spdr.c,1219,SpGetLen error, rc=-109 (ErrorCode=109 The pipe has
been ended.)
102340,RESP,ntbackend.c,720,Resp1 killing pid=122680
102340,RESP,ntbackend.c,701,WriteFile (ErrorCode=232 The pipe is being
closed.)
102340,RESP,ntbackend.c,769,Sent 0 stop failed. (ErrorCode=232 The pipe is
being closed.)
102340,RESP,ntbackend.c,626,try SafeTerminateProcess (ErrorCode=232 The
pipe is being closed.)
102340,RESP,ntbackend.c,630,Did not respond to SafeTerminateProcess: try
TerminateProcess (gag) (ErrorCode=232 The pipe is being closed.)
102340,RESP,ntbackend.c,633,TerminateProcess (ErrorCode=5 Access is
denied.)
102340,RESP,ntbackend.c,790,Resp1 kill of pid=0 complete, rc=1.
102340,SCHD,ntresp.c,368,2.child slot=6 thandle=-1
102340,SCHD,ntresp.c,370,child died aidx=3
102340,RESP,respcmn.c,428,Responder terminating now.
Is there a way to capture a better error message?
David A. Green
(480) 813-1725
DAG Consulting
_______________________________________________
U2-Users mailing list
U2-Users@listserver.u2ug.org
http://listserver.u2ug.org/mailman/listinfo/u2-users
_______________________________________________
U2-Users mailing list
U2-Users@listserver.u2ug.org
http://listserver.u2ug.org/mailman/listinfo/u2-users