Issue: Tower down due to reset Rocket after a short regional power outage
Christmas morning.

Solution: Factory Reset Master PtP Rocket... Change to AP, change channel
to what it was, set mileage. Change IP to what it was... Leave everything
else as is... SSID UBNT, CW 40, etc... save settings and it will reconnect
to factory reset Rocket downstream. Then just program everything back like
it was (or restore from AC2 backup). Note, you will need subnet access to
192.168.1.x via computer and routers.

No go and call back the three dozen angry people who called in on Christmas
morning.

Lucked out that the 40 CW still let me connect, although dur no the fix it
knocked down couple other backhauls. Be nice if Ubiquiti  would have
factory default of 10.

Now off to fix a factory reset router, which I will do by routing to
192.168.10.1, remotely, and then reprogram. (Need to turn all those factory
reset buttons off!)



-- 


-- 
Clay Stewart, CEO
SCS Broadband
  434.263.6363 O
  434.942.6510 C
  cstew...@scsbroadband.com
“We Keep You Up and Running”

Please send sales inquiries to sa...@scsbroadband.com
Please send service/repair requests to supp...@scsbroadband.com
_______________________________________________
Ubnt_users mailing list
Ubnt_users@wispa.org
http://lists.wispa.org/mailman/listinfo/ubnt_users