Ports 1-4 of a Edgepoint 16 are either 24vdc 4 wire or 48vdc 4 wire power. So I assume that ports 1-4 cannot be used to power a Rocket Prism AC which is 24vdc 2 wire plus return on 7/8 wires?
Wouldn't even ask question except someone (me), accidentally plugged 2 Rocket Prism ACs in ports 3 and 4 of the EdgePoint 16. Caught it before powering the ports, but it does mean a 185' climb to switch the ports! So I thought I would ask the stupid question anyhow, since the temps are coming down to late Autumn levels. (What happened to winter?) Bonus question. -- -- Clay Stewart, COO/CTO SCS Broadband A Division of Acelanet, LLC 434.263.6363 O 434.942.6510 C cstew...@scsbroadband.com “We Keep You Up and Running” Please send sales inquiries to sa...@scsbroadband.com Please send service/repair requests to supp...@scsbroadband.com