It is passive 24 and 54v on port 1 thru 4.

I am fairly certain that it will reset the AC prism similar to you holding down 
the reset on the POE.

Shawn C. Peppers
Video Direct Satellite & Entertainment
866-680-8433 Toll Free
480-287-9960 Fax
http://www.video-direct.tv

> On Jan 26, 2017, at 10:10 PM, Clay Stewart 
> <cstew...@stewartcomputerservices.com> wrote:
> 
> Ports 1-4 of a Edgepoint 16 are either 24vdc 4 wire or 48vdc 4 wire power.
> 
> So I assume that ports 1-4 cannot be used to power a Rocket Prism AC which is 
> 24vdc 2 wire plus return on 7/8 wires?
> 
> Wouldn't even ask question except someone (me), accidentally plugged 2 Rocket 
> Prism ACs in ports 3 and 4 of the EdgePoint 16. Caught it before powering the 
> ports, but it does mean a 185' climb to switch the ports! So I thought I 
> would ask the stupid question anyhow, since the temps are coming down to late 
> Autumn levels. (What happened to winter?) Bonus question.
> -- 
> 
> 
> -- 
> Clay Stewart, COO/CTO
> SCS Broadband
> A Division of Acelanet, LLC
>   434.263.6363 O 
>   434.942.6510 C
>   cstew...@scsbroadband.com 
> “We Keep You Up and Running” 
> 
> Please send sales inquiries to sa...@scsbroadband.com
> Please send service/repair requests to supp...@scsbroadband.com
> _______________________________________________
> Ubnt_users mailing list
> Ubnt_users@wispa.org
> http://lists.wispa.org/mailman/listinfo/ubnt_users
_______________________________________________
Ubnt_users mailing list
Ubnt_users@wispa.org
http://lists.wispa.org/mailman/listinfo/ubnt_users

Reply via email to