Насколько я понимаю, посыпался хард-
196 Reallocated_Event_Count 0x0032   159   159   000    Old_age
Always       -       41
эта надпись говорит о том, что 41 раз происходила замена битых секторов.
Если это число будет расти - меняйте хард.

2008/2/6, sergicus s <[EMAIL PROTECTED]>:
>
> Недавно постаил на сервер ubuntu 7.1- server
> потихоньку с ней работал
> начал проверять smart
>
> sudo smartctl -a /dev/hda
>
> smartctl version 5.37 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
> Home page is http://smartmontools.sourceforge.net/
>
> === START OF INFORMATION SECTION ===
> Model Family:     Western Digital Caviar family
> Device Model:     WDC WD600BB-00CAA1
> Serial Number:    WD-WMA8E7857660
> Firmware Version: 17.07W17
> User Capacity:    60 022 480 896 bytes
> Device is:        In smartctl database [for details use: -P show]
> ATA Version is:   5
> ATA Standard is:  Exact ATA specification draft version not indicated
> Local Time is:    Wed Feb  6 09:59:53 2008 MSK
> SMART support is: Available - device has SMART capability.
> SMART support is: Enabled
>
> === START OF READ SMART DATA SECTION ===
> SMART overall-health self-assessment test result: PASSED
> See vendor-specific Attribute list for marginal Attributes.
>
> General SMART Values:
> Offline data collection status:  (0x84) Offline data collection activity
>                                         was suspended by an interrupting
> command from host.
>                                         Auto Offline Data Collection:
> Enabled.
> Self-test execution status:      (   0) The previous self-test routine
> completed
>                                         without error or no self-test has
> ever
>                                         been run.
> Total time to complete Offline
> data collection:                 (2340) seconds.
> Offline data collection
> capabilities:                    (0x3b) SMART execute Offline immediate.
>                                         Auto Offline data collection
> on/off support.
>                                         Suspend Offline collection upon
> new
>                                         command.
>                                         Offline surface scan supported.
>                                         Self-test supported.
>                                         Conveyance Self-test supported.
>                                         No Selective Self-test supported.
> SMART capabilities:            (0x0003) Saves SMART data before entering
>                                         power-saving mode.
>                                         Supports SMART auto save timer.
> Error logging capability:        (0x01) Error logging supported.
>                                         No General Purpose Logging
> support.
> Short self-test routine
> recommended polling time:        (   2) minutes.
> Extended self-test routine
> recommended polling time:        (  43) minutes.
> Conveyance self-test routine
> recommended polling time:        (   5) minutes.
>
> SMART Attributes Data Structure revision number: 16
> Vendor Specific SMART Attributes with Thresholds:
> ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED
> WHEN_FAILED RAW_VALUE
>   1 Raw_Read_Error_Rate     0x000b   200   001   051    Pre-fail  Always
> In_the_past 0
>   3 Spin_Up_Time            0x0007   100   094   021    Pre-fail
> Always       -       4058
>   4 Start_Stop_Count        0x0032   100   100   040    Old_age
> Always       -       372
>   5 Reallocated_Sector_Ct   0x0033   180   180   140    Pre-fail
> Always       -       316
>   7 Seek_Error_Rate         0x000b   100   253   051    Pre-fail
> Always       -       0
>   9 Power_On_Hours          0x0032   050   050   000    Old_age
> Always       -       36921
>  10 Spin_Retry_Count        0x0013   100   100   051    Pre-fail
> Always       -       0
>  11 Calibration_Retry_Count 0x0013   100   100   051    Pre-fail
> Always       -       0
>  12 Power_Cycle_Count       0x0032   100   100   000    Old_age
> Always       -       220
> 196 Reallocated_Event_Count 0x0032   159   159   000    Old_age
> Always       -       41
> 197 Current_Pending_Sector  0x0012   189   186   000    Old_age
> Always       -       108
> 198 Offline_Uncorrectable   0x0012   189   188   000    Old_age
> Always       -       108
> 199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age
> Always       -       65
> 200 Multi_Zone_Error_Rate   0x0009   200   200   051    Pre-fail
> Offline      -       0
>
> SMART Error Log Version: 1
> ATA Error Count: 5945 (device log contains only the most recent five
> errors)
>         CR = Command Register [HEX]
>         FR = Features Register [HEX]
>         SC = Sector Count Register [HEX]
>         SN = Sector Number Register [HEX]
>         CL = Cylinder Low Register [HEX]
>         CH = Cylinder High Register [HEX]
>         DH = Device/Head Register [HEX]
>         DC = Device Command Register [HEX]
>         ER = Error register [HEX]
>         ST = Status register [HEX]
> Powered_Up_Time is measured from power on, and printed as
> DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
> SS=sec, and sss=millisec. It "wraps" after 49.710 days.
>
> Error 5945 occurred at disk power-on lifetime: 1020 hours (42 days + 12
> hours)
>   When the command that caused the error occurred, the device was doing
> SMART Offline or Self-test.
>
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 10 63 0c 39 e2  Error: UNC at LBA = 0x02390c63 = 37293155
>
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   40 00 10 5f 0c 39 e2 00      11:01:39.800  READ VERIFY SECTOR(S)
>   40 00 10 4f 0c 39 e2 00      11:01:39.800  READ VERIFY SECTOR(S)
>   40 00 20 2f 12 39 e2 00      11:01:39.750  READ VERIFY SECTOR(S)
>   40 00 20 0f 12 39 e2 00      11:01:36.900  READ VERIFY SECTOR(S)
>   40 00 20 2f 0f 39 e2 00      11:01:34.200  READ VERIFY SECTOR(S)
>
> Error 5944 occurred at disk power-on lifetime: 1020 hours (42 days + 12
> hours)
>   When the command that caused the error occurred, the device was doing
> SMART Offline or Self-test.
>
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 20 15 12 39 e2  Error: UNC at LBA = 0x02391215 = 37294613
>
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   40 00 20 0f 12 39 e2 00      11:01:36.900  READ VERIFY SECTOR(S)
>   40 00 20 2f 0f 39 e2 00      11:01:34.200  READ VERIFY SECTOR(S)
>   40 00 20 0f 0f 39 e2 00      11:01:34.200  READ VERIFY SECTOR(S)
>   40 00 20 6f 0c 39 e2 00      11:01:34.200  READ VERIFY SECTOR(S)
>   40 00 20 4f 0c 39 e2 00      11:01:31.500  READ VERIFY SECTOR(S)
>
> Error 5943 occurred at disk power-on lifetime: 1020 hours (42 days + 12
> hours)
>   When the command that caused the error occurred, the device was doing
> SMART Offline or Self-test.
>
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 20 3c 0f 39 e2  Error: UNC at LBA = 0x02390f3c = 37293884
>
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   40 00 20 2f 0f 39 e2 00      11:01:34.200  READ VERIFY SECTOR(S)
>   40 00 20 0f 0f 39 e2 00      11:01:34.200  READ VERIFY SECTOR(S)
>   40 00 20 6f 0c 39 e2 00      11:01:34.200  READ VERIFY SECTOR(S)
>   40 00 20 4f 0c 39 e2 00      11:01:31.500  READ VERIFY SECTOR(S)
>   40 00 40 4f 12 39 e2 00      11:01:31.500  READ VERIFY SECTOR(S)
>
> Error 5942 occurred at disk power-on lifetime: 1020 hours (42 days + 12
> hours)
>   When the command that caused the error occurred, the device was doing
> SMART Offline or Self-test.
>
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 20 63 0c 39 e2  Error: UNC at LBA = 0x02390c63 = 37293155
>
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   40 00 20 4f 0c 39 e2 00      11:01:31.500  READ VERIFY SECTOR(S)
>   40 00 40 4f 12 39 e2 00      11:01:31.500  READ VERIFY SECTOR(S)
>   40 00 40 0f 12 39 e2 00      11:01:28.950  READ VERIFY SECTOR(S)
>   40 00 40 4f 0f 39 e2 00      11:01:28.950  READ VERIFY SECTOR(S)
>   40 00 40 0f 0f 39 e2 00      11:01:26.300  READ VERIFY SECTOR(S)
>
> Error 5941 occurred at disk power-on lifetime: 1020 hours (42 days + 12
> hours)
>   When the command that caused the error occurred, the device was doing
> SMART Offline or Self-test.
>
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 40 15 12 39 e2  Error: UNC at LBA = 0x02391215 = 37294613
>
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   40 00 40 0f 12 39 e2 00      11:01:28.950  READ VERIFY SECTOR(S)
>   40 00 40 4f 0f 39 e2 00      11:01:28.950  READ VERIFY SECTOR(S)
>   40 00 40 0f 0f 39 e2 00      11:01:26.300  READ VERIFY SECTOR(S)
>   40 00 40 4f 0c 39 e2 00      11:01:23.650  READ VERIFY SECTOR(S)
>   40 00 40 0f 0c 39 e2 00      11:01:23.650  READ VERIFY SECTOR(S)
>
> SMART Self-test log structure revision number 1
> No self-tests have been logged.  [To run self-tests, use: smartctl -t]
>
>
> Device does not support Selective Self Tests/Logging
>
>
>
> Вывелись ошибки - посоветуйте что они значат
>
>
> --
> С уважением
> Сергей
> --
> ubuntu-ru mailing list
> ubuntu-ru@lists.ubuntu.com
> https://lists.ubuntu.com/mailman/listinfo/ubuntu-ru
>
>
-- 
ubuntu-ru mailing list
ubuntu-ru@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-ru

Дати відповідь електронним листом