Hi Lupco;
 
There is no mention of a multipath driver (which for AIX, should be RDAC
ideally).
 
If configured correctly, and MP setup correctly the below will work. You
won't have
any outage during LUN failover - if it's setup correctly.
 
I'm pretty sure that the VG on the AIX will be a concat;however, it really
depends on
the allocation of LEs/PEs and how they've been allocated to the various
lvols.
 
So yes, it should work.
 
Will it perform the way you hope it weill? Depends. What do you want it do
be able to do?
 
gunther :)
 

-----Original Message-----
From: [email protected]
[mailto:ug-msosug-bounces at opensolaris.org] On Behalf Of Lupco Trpeski
Sent: Thursday, 19 November 2009 1:31 PM
To: Nathan Kroenert
Cc: ug-msosug at opensolaris.org
Subject: [ug-msosug] Engenio disk array configuration


Hi All,

Let me start my apologizing for spamming this email alias. I really would
like a second opinion on this if you know abit about San's.

Basically we have a Engenio disk array connect to an IBM P Series box. The
Disk array has 2 x 200GB Raid 1 Luns. One lun is on Controller A and one lun
is on Controller B.

Both luns have been added to the same volume group under AIX and there is a
400GB file system created on the volume group. I'm assuming that AIX sees
that as a Concatenation of both luns.

What are people thoughts on this configuration, because my first impression
was:
- Controller Failure on either controller would cause a short outage on one
of the luns while the path was changed to the redundant controller.
- Loss of either of the luns would result in an unreadable file system.

Regards,
Lupco Trpeski



  _____  

With all the lastest places, searching has never been easier. Look now!
Looking to  <http://clk.atdmt.com/NMN/go/157631292/direct/01/> move this
spring? 

-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://mail.opensolaris.org/pipermail/ug-msosug/attachments/20091119/88e15682/attachment.html>

Reply via email to