Thx Matty! Appreciate your help!

-----Ursprüngliche Nachricht-----
Von: Marty Sweet [mailto:msweet....@gmail.com] 
Gesendet: Dienstag, 21. Januar 2014 17:15
An: users@cloudstack.apache.org
Betreff: Re: management server DB timeout

Hi,

>From the managment server point of view (as I see it), it would have to stop
all communication to Agents and the like if it wished to do that, as the
data would become inconsistent with other Management Servers. I would
imagine this is too much work to implement, but I'm sure one of the
development guys will provide a better insight.

I currently implement the following work around:

___ Root Crontab ___
* * * * * /srv/csmanagement-watchdog

___ /srv/csmanagement-watchdog ___
#!/bin/bash
# If Cloudstack Management is not running, start it if [ ! -e
"/var/run/cloudstack-management.pid" ]; then
        service cloudstack-management start fi



Hope this helps,
Marty









On Tue, Jan 21, 2014 at 4:03 PM, Abu Bashiri
<abu.bashiri...@gmail.com>wrote:

> Hey Marty,
>
> thx for your reply. I mean, in general the self-fence make sense but i 
> was looking for a way to say "try to reconnect for 60seconds".
> Would be cool if you can paste your solution here!
>
>
> Thx
>
> -----Ursprüngliche Nachricht-----
> Von: Marty Sweet [mailto:msweet....@gmail.com]
> Gesendet: Dienstag, 21. Januar 2014 15:54
> An: users@cloudstack.apache.org
> Betreff: Re: management server DB timeout
>
> Hi,
>
> I have this problem with my failover setup, I think however it's by 
> design to ensure data consistency and is more that the MySQL 
> connections have disappeared instead of it timing out.
>
> I ended up creating a cron watchdog to start CS Management incase it 
> stopped, I'm sure there are more elegant solutions however, maybe 
> using upstart. If you wish I can paste it here.
>
> Marty
>
> On Tuesday, January 21, 2014, Abu Bashiri <abu.bashiri...@gmail.com>
> wrote:
>
> > Hey Guys,
> >
> >
> >
> > just some short question. Is there a way to increase the DB timeout 
> > for the management server?
> >
> >
> >
> > I use mha for mysql master / slave automatic failover. Everything 
> > works but everytime I perform a master failover and the virtual IP 
> > changes, the management server shows me immediately the following:
> >
> >
> >
> > DB communication problem detected, fence it
> >
> > 2014-01-21 14:19:51,502 DEBUG [cloud.cluster.ClusterManagerImpl]
> > (Cluster-Notification-1:null) Notify management server node 
> > isolation to listeners
> >
> > 2014-01-21 14:19:51,503 ERROR 
> > [cloud.cluster.ClusterFenceManagerImpl]
> > (Cluster-Notification-1:null) Received node isolation notification, 
> > will perform self-fencing and shut myself down
> >
> >
> >
> >
> >
> > Can we avoid that self-fencing?
> >
> >
> >
> > I already had a look at db.properties file but I cannot find a 
> > timeout value.
> >
> >
> >
> > thx
> >
> >
>
>