Interesting. What errors/exceptions do you see in the producer logs?

Thanks,
Neha


On Tue, Sep 3, 2013 at 3:28 PM, Rajasekar Elango <rela...@salesforce.com>wrote:

> We found a issue that if broker host is un resolvable, the number of file
> handle keep increasing for every message we produce and eventually it uses
> up all available files handles in operating system. If broker itself is not
> running and broker host name is resolvable, open file handles count stays
> flat.
>
> lsof output shows number of these open file handles continue to grow for
> every message we produce.
>
>  java      19631    relango   81u     sock                0,6      0t0
>  196966526 can't identify protocol
>
> Is this a bug is producer API..? What is best way to self protect our self
> ?
>
> --
> Thanks,
> Raja.
>

Reply via email to