Thanks for your help Alvaro and Nikos. I now have bearerbox running using the following modem configuration:
group = modems id = ericsson_f3607gw name = "Ericsson F3607gw" detect-string = "F3607gw" init-string = "AT+CNMI=2,3,2,0,0" -Chris On Wed, Aug 3, 2011 at 15:37, Alvaro Cornejo <cornejo.alv...@gmail.com>wrote: > Sorry didn't read all your mail... missed the links ;) > > > It is because your modem does not support the AT+CNMI=1,2,0,1,0 command. > > Either check with your modem vendor the allowed values for the command > or try with another values. > > As for the going auto, it is because you modem identifes itself as > "F3607gw" and there is no definition for such modem in your config. > You can just copy an entry for another modem with that string as its > detect-string. Then change other settings according to your modems. > > Regards > > Alvaro > > > > > |-----------------------------------------------------------------------------------------------------------------| > Envíe y Reciba Datos y mensajes de Texto (SMS) hacia y desde cualquier > celular y Nextel > en el Perú, México y en mas de 180 paises. Use aplicaciones 2 vias via > SMS y GPRS online > Visitenos en www.perusms.NET www.smsglobal.com.mx y > www.pravcom.com > > > > On Wed, Aug 3, 2011 at 4:30 PM, Alvaro Cornejo <cornejo.alv...@gmail.com> > wrote: > > Hi > > > > Post logs of modem init as well as config files. At least modem config. > > > > > > > |-----------------------------------------------------------------------------------------------------------------| > > Envíe y Reciba Datos y mensajes de Texto (SMS) hacia y desde cualquier > > celular y Nextel > > en el Perú, México y en mas de 180 paises. Use aplicaciones 2 vias via > > SMS y GPRS online > > Visitenos en www.perusms.NET www.smsglobal.com.mx y > > www.pravcom.com > > > > > > > > On Wed, Aug 3, 2011 at 4:13 PM, Chris Blay <ch...@meosphere.com> wrote: > >> On Wed, Aug 3, 2011 at 15:08, Chris Blay <ch...@meosphere.com> wrote: > >>> > >>> Hey all, > >>> > >>> I have been trying to configure Kannel to use an Ericsson F3607gw modem > >>> for sending/receiving SMS/MMS messages. As far as I can tell, there is > no > >>> specific modem configuration for this device. When I run bearerbox > using > >>> 'generic' for the modem type, it determines that it should use the > generic > >>> modem configuration and gets stuck in a loop due to "CMS ERROR: > Operation > >>> not supported (303)". I'm still getting aquainted with Kannel so I hope > that > >>> I've just missed something obvious. Any help would be most appreciated. > >>> > >>> kannel.conf - http://pastebin.com/JV8xYywA > >>> Terminal Log - http://pastebin.com/ayZHV6zK > >>> * both pastebins will expire in one month * > >>> > >>> Thanks, > >>> Christopher Blay > >>> ch...@meosphere.com > >> > >> Sorry I meant to say "when I run bearerbox using 'auto' for the modem > type". > >> You can see 'auto' specified in kannel.conf but I just wanted to clarify > >> that here. > >> -Chris > >> > > >