Hi Long Qingyang,
 
Please see the following sample configuration using snmp mibsets to
configure a component, csi, SU, SI and all. There are dependencies
between different-different mib configurations so you need to make sure
that the configuration is done in a particular order as mentioned
below(Either follow the mib descriptions). You may add a complete new
configuration or you can modify the existing one. Every mib object
description talks about if it has any dependency, if you do not want to
look into mib files than follow the configuration order mentioned below.

 
Thanks- Arya
 
Node Configuration: (Configure as many as node is needed)
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfNodeSuFailoverMax.\"safNode=PL_2_3\" u 2
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfNodeSuFailoverProb.\"safNode=PL_2_3\" x
"00 00 03 A3 52 94 40 00"
snmpset -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB localhost
SAF-AMF-MIB::saAmfNodeAdminState.\"safNode=PL_2_3\" i 2
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 NCS-AVSV-MIB::ncsNDNodeId.\"safNode=PL_2_3\" u 3
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfNodeRowStatus.\"safNode=PL_2_3\" i 1
 
SG Configuratin: (Configure SGs )
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSGRedModel.\"safSg=SG_TEST\" i 1
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSGNumPrefInserviceSUs.\"safSg=SG_TEST\"
u 2
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSGCompRestartProb.\"safSg=SG_TEST\" x
"00 00 03 A3 52 94 40 00"
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSGSuRestartProb.\"safSg=SG_TEST\" x "00
00 03 A3 52 94 40 00"
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSGCompRestartMax.\"safSg=SG_TEST\" u 10
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSGSuRestartMax.\"safSg=SG_TEST\" u 10
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSGRowStatus.\"safSg=SG_TEST\" i 1
 
SU Configuration: (Configure SUs on a node or different nodes)
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSURank.\"safSu=SuT_TEST,safNode=PL_2_3\"
u 1 
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfSUNumComponents.\"safSu=SuT_TEST,safNode=PL_2_3\" u 1
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfSUParentSGName.\"safSu=SuT_TEST,safNode=PL_2_3\" s
"safSg=SG_TEST"
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfSURowStatus.\"safSu=SuT_TEST,safNode=PL_2_3\" i 1
 
SI Configuration: (Configure SIs)
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSIRank.\"safSi=Si_TEST\" u 1
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSINumCSIs.\"safSi=Si_TEST\" u 1
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSIParentSGName.\"safSi=Si_TEST\" s
"safSg=SG_TEST"
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSIRowStatus.\"safSi=Si_TEST\" i 1
 
CSI Configuration:  (Configure CSIs )
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfCSType.\"safCsi=Csi_TEST,safSi=Si_TEST\"
s "safCsi=Csi_TEST"
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCSIRank.\"safCsi=Csi_TEST,safSi=Si_TEST\" u 1
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCSIRowStatus.\"safCsi=Csi_TEST,safSi=Si_TEST\" i 1
 
SUsPerSI Configuration: 
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSUsperSISUName.\"safSi=Si_TEST\".1 s
"safSu=SuT_TEST,safNode=PL_2_3"
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186 SAF-AMF-MIB::saAmfSUsperSIRowStatus.\"safSi=Si_TEST\".1 i
1
 
CSTypeParam Configuration:
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompCSTypeSupportedRowStatus.\"safComp=CompT_TEST,safS
u=SuT_TEST,safNode=PL_2_3\".\"safCsi=Csi_TEST\" i 4
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCSTypeParamRowStatus.\"safCsi=Csi_TEST\".\"test\" i 4
 
Component Configuration: (Configure components)
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompCapability.\"safComp=CompT_TEST,safSu=SuT_TEST,saf
Node=PL_2_3\" i 4
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompCategory.\"safComp=CompT_TEST,safSu=SuT_TEST,safNo
de=PL_2_3\" i 0
nmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompInstantiateCmd.\"safComp=CompT_TEST,safSu=SuT_TEST
,safNode=PL_2_3\" s "/home/g20265/comp_clc/test_1.sh"
 
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompCleanupCmd.\"safComp=CompT_TEST,safSu=SuT_TEST,saf
Node=PL_2_3\" s "/home/g20265/comp_clc/comp_term.pl"
 
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompTerminateTimeout.\"safComp=CompT_TEST,safSu=SuT_TE
ST,safNode=PL_2_3\" x "00 00 03 A3 52 94 40 00"
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompNumMaxInstantiate.\"safComp=CompT_TEST,safSu=SuT_T
EST,safNode=PL_2_3\" u 5
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompNumMaxActiveCsi.\"safComp=CompT_TEST,safSu=SuT_TES
T,safNode=PL_2_3\" u 1
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompNumMaxStandbyCsi.\"safComp=CompT_TEST,safSu=SuT_TE
ST,safNode=PL_2_3\" u 1
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompAMEnable.\"safComp=CompT_TEST,safSu=SuT_TEST,safNo
de=PL_2_3\" i 2
snmpset   -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB -r 0
10.232.92.186
SAF-AMF-MIB::saAmfCompRowStatus.\"safComp=CompT_TEST,safSu=SuT_TEST,safN
ode=PL_2_3\" i 1
 


________________________________

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Long, Qing Yang
(TSG-GDCC-SH/CMEP)
Sent: Thursday, October 25, 2007 8:23 PM
To: Sreenivasan Prabhu-G20200; [email protected]
Subject: Re: [Users] Adding a node to OpenSAF cluster



         
        Thanks Prabhu.
        These commands you provide works well. Paynode "PL_2_20" can run
up.
         
        But this is only basic configuration.  No application is
configured on this node. It is empty and useless.  
        And only one OpenSAF process is running:
"/opt/opensaf/payload/bin/ncs_pcap NID_SVC_ID=18".
         
        Some HA-Aware applications should be added to this node. 
        How to add "service group", "service unit", "service instance"
etc. including all kinds of software components?  
        For example: "CompT_SC_CPND", "CompT_SC_MQND", "CompT_SC_GLND",
"safComp=CompT_IFND", "safComp=CompT_EDS", 
         "safComp=CompT_AvSvDemo" etc.
         
        When "PL_2_20" is running, it is just like "PL_2_3" which is
configured by XML files. How to configure these software components
using snmpset? 
         
        Best regards.
         

Long Qingyang

________________________________

From: Sreenivasan Prabhu-G20200 [mailto:[EMAIL PROTECTED] 
Sent: Thursday, October 25, 2007 9:04 PM
To: Long, Qing Yang (TSG-GDCC-SH/CMEP); [email protected]
Subject: RE: [Users] Adding a node to OpenSAF cluster


Hi Long Qingyang

 
You can configure a running opens system using MIBS. 
 
for example to add a node configuration dynamically on a running system.
say to add a payload node on slot 20 (0x02140f), give the following SNMP
commands on your active controller.
 
snmpset -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB localhost
SAF-AMF-MIB::saAmfNodeSuFailoverProb.\"safNode=PL_2_20\" x "00 00 00 00
05 F5 E1 00"
snmpset -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB localhost
SAF-AMF-MIB::saAmfNodeSuFailoverMax.\"safNode=PL_2_20\" u 2
snmpset -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB localhost
SAF-AMF-MIB::saAmfNodeAdminState.\"safNode=PL_2_20\" i 2
snmpset -v2c -c public -m /usr/share/snmp/mibs/NCS-AVSV-MIB localhost
NCS-AVSV-MIB::ncsNDNodeId.\"safNode=PL_2_20\" u 134928
snmpset -v2c -c public -m /usr/share/snmp/mibs/SAF-AMF-MIB localhost
SAF-AMF-MIB::saAmfNodeRowStatus.\"safNode=PL_2_20\" i 1
 
after wards you need to add SU's, components etc.. on this new node.
Refer SAF-AMF-MIB & NCS-AVSV-MIB for more details.
 
Note: copy all mibs to /usr/share/snmp/mibs on active controller
         export MIBDIRS=/usr/share/snmp/mibs from your shell.
 
Thanks
Prabhu

________________________________

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Long, Qing Yang
(TSG-GDCC-SH/CMEP)
Sent: Thursday, October 25, 2007 6:56 AM
To: [email protected]
Subject: [Users] Adding a node to OpenSAF cluster


Hello friends,
I need your help about the following questions

1. OpenSAF uses NCSSystemBOM.xml and AppConfig.xml to configure a 
cluster node and software components.
How to achieve this function: Add a node to OpenSAF cluster when 
OpenSAF is running ?
Do you have C language program which implementing this function?

2. Or do you have a step by step operation guide to add a node to 
OpenSAF cluster manually?


Thanks.