Hi,


It seems such a reporting task is not yet implemented.



I wonder if you need only output to syslog, can’t this be configured adding
*SyslogAppender* to logback.xml configuration?



And maybe new Logger is also needed in logback.xml?

Which might be Logger name?



Thanks

Toivo



2017-04-11 9:31 GMT+03:00 HARRIOTT, John <john.harri...@baesystems.com>:

> Hi Joe,
>
> What is meant by the following statement: "From that one can access the
> list of changes from a given offset onward."
> ReportingTask.java is an interface class. That does mean there exists a
> class specifically for reporting configuration changes?
>
> Regards John
>
> -----Original Message-----
> From: Joe Witt [mailto:joe.w...@gmail.com]
> Sent: Tuesday, 11 April 2017 4:02 AM
> To: users@nifi.apache.org
> Subject: Re: Logging changes to workflow
>
> Juan,
>
> They were introduced in https://issues.apache.org/jira/browse/NIFI-986
>
> I don't know if there is a reporting task which leverages this yet but the
> key classes to notice are here:
>  ReportingTask [1]
>  EventAccess [2]
>
> From that one can access the list of changes from a given offset onward.
>
> [1] https://github.com/apache/nifi/blob/master/nifi-api/src/
> main/java/org/apache/nifi/reporting/ReportingTask.java
> [2] https://github.com/apache/nifi/blob/master/nifi-api/src/
> main/java/org/apache/nifi/reporting/EventAccess.java
>
> Thanks
> Joe
>
> On Mon, Apr 10, 2017 at 2:25 PM, Juan Sequeiros <helloj...@gmail.com>
> wrote:
> > Hi Joe / all,
> >
> > " we make it available via reporting tasks "
> >
> > What reporting task is that? I've looked at NIFI 1 available reporting
> > tasks and I don't see anything that would let me export "flow
> > configuration history".
> > Coincidentally we are having to meet similar requirement.
> >
> > Our solution was to get that through restAPI but if there is a cleaner
> > way though reporting tasks, would like to experiment with that too.
> >
> > On Mon, Apr 10, 2017 at 9:09 AM Joe Witt <joe.w...@gmail.com> wrote:
> >>
> >> John
> >>
> >> To build on Andrew's comments there is already a very significant
> >> amount of audit data made available for flow changes.  We store this
> >> in an audit database so we can drive some user experiences off it and
> >> we make it available via reporting tasks so one could report this
> >> information to an external system.  I believe what you're asking for
> >> is well supported.
> >>
> >> In addition to that sort of configuraiton auditing remember too we
> >> have actual data provenance which shows not just what the
> >> configuration was but the lineage/path that data actually takes.
> >> These too together form an extremely powerful audit basis.
> >>
> >> Thanks
> >> Joe
> >>
> >> On Mon, Apr 10, 2017 at 9:05 AM, Andrew Grande <apere...@gmail.com>
> wrote:
> >> > John, the Flow Configuration History menu item already captures it.
> >> > Does it look like a fit?
> >> >
> >> > Andrew
> >> >
> >> >
> >> > On Sun, Apr 9, 2017, 10:50 PM HARRIOTT, John
> >> > <john.harri...@baesystems.com>
> >> > wrote:
> >> >>
> >> >> Is it possible to log changes to a workflow so they can be
> >> >> captured by a central logging/auditing capability e.g. syslog.
> >> >>
> >> >> This will allow security auditors to detect changes to a systems
> >> >> configuration e.g. addition/removal/modification of a processor(s).
> >> >>
> >> >>
> >> >>
> >> >> Thanks
> >> >>
> >> >>
> >> >>
> >> >>
> >> >>
> >> >>
> >> >>
> >> >> This email has been sent on behalf of one of the following
> >> >> companies within the BAE Systems Australia group of companies:
> >> >>
> >> >>     BAE Systems Australia Limited - Australian Company Number 008
> >> >> 423
> >> >> 005
> >> >>     BAE Systems Australia Defence Pty Limited - Australian Company
> >> >> Number
> >> >> 006 870 846
> >> >>     BAE Systems Australia Logistics Pty Limited - Australian
> >> >> Company Number 086 228 864
> >> >>
> >> >> Our registered office is Evans Building, Taranaki Road, Edinburgh
> >> >> Parks, Edinburgh, South Australia, 5111. If the identity of the
> >> >> sending company is not clear from the content of this email please
> >> >> contact the sender.
> >> >>
> >> >> This email and any attachments may contain confidential and
> >> >> legally privileged information.  If you are not the intended
> >> >> recipient, do not copy or disclose its content, but please reply
> >> >> to this email immediately and highlight the error to the sender
> >> >> and then immediately delete the message.
> This email has been sent on behalf of one of the following companies
> within the BAE Systems Australia group of companies:
>
>     BAE Systems Australia Limited - Australian Company Number 008 423 005
>     BAE Systems Australia Defence Pty Limited - Australian Company Number
> 006 870 846
>     BAE Systems Australia Logistics Pty Limited - Australian Company
> Number 086 228 864
>
> Our registered office is Evans Building, Taranaki Road, Edinburgh Parks,
> Edinburgh, South Australia, 5111. If the identity of the sending company is
> not clear from the content of this email please contact the sender.
>
> This email and any attachments may contain confidential and legally
> privileged information.  If you are not the intended recipient, do not
> copy or
> disclose its content, but please reply to this email immediately and
> highlight
> the error to the sender and then immediately delete the message.
>

Reply via email to