Just to be clear, you see these pulsations when transmitting with a
b205mini, but *not* with the b210?

Is the b205mini a bare board or an industrial model with a case and
aluminum heat sync?

Sam Reiter
Ettus Research


On Wed, Dec 11, 2019 at 11:48 PM Геннадий Казачёк via USRP-users <
usrp-users@lists.ettus.com> wrote:

> Hello!
> I'm trying to build QPSK based system on GNURadio.
> I'm using two USRP B205-mini boards as transmitter and receiver, also I
> got B210 board that I run gqrx on to watch what is really going on.
> I noticed a strange behaviour on my tests, so I began to investigate it
> and ended to a very simple graph, that is in attachment. On a frequencies
> that are multiple of 10Mhz, like 1020Mhz all works like expected and
> sonogram looks good. If I tune to any other frequency, even 1Hz more or
> less, the sonogram is full of pulsations and frequency of that pulsation is
> depends of exact tune frequency. I attached some screenshots of that
> pulsations.
> On receiving part that pulsations cause many errors while decoding.
> I got another board, LimeSDR-Mini, and no such behaviour observed while
> running graph on it.
> I wonder what is going on, and how can I fix this problem.
> Thank you.
> _______________________________________________
> USRP-users mailing list
> USRP-users@lists.ettus.com
> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
>
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to