On 11/13/2020 03:48 PM, Jerrid Plymale via USRP-users wrote:

Hello All,

So I have been working on transitioning to using UHD 4.0 from 3.15, and I am running into a problem. I was able to get the software updated without issue, then I downloaded the new FPGA images using the uhd_image_downloader and updated the two USRP X310’s I am working with. After that I tried running one of my flowgraphs in GRC and I get the following: RuntimeError: Expected FPGA Compatibility number 36, but got 38. So do I need to update UHD again to a newer version, or is there a way I can install the older versions of the FPGA Image?

Best Regards,

Jerrid


My guess is that while you compiled/built/installed UHD 4.0, your Gnu Radio environment is still linked against UHD 3.15.

You'll need to at least re-link.


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to