> The staged virtio-snd capture path needs to sample stop_threshold from
> completion context to distinguish free-running capture from bounded
> capture. Software parameters can update this field while capture runs.
> 
> Mark the runtime stop-threshold assignments with WRITE_ONCE and the proc
> status read with READ_ONCE. This pairs the assignments with the driver's
> READ_ONCE policy sampling in the following patch.
> 
> These annotations do not provide a transaction for the entire sw_params
> update. The driver serializes its cached policy and accounting with its
> own substream lock.
> 
> Assisted-by: LLM
> Signed-off-by: Joonho Lee <[email protected]>

Sashiko has reviewed this patch and found no issues.

-- 
Sashiko AI review ยท 
https://sashiko.dev/#/patchset/[email protected]?part=10


Reply via email to