> A driver which keeps private capture counters needs to reset those
> counters together with the PCM application's position. The ioctl RESET
> path releases the stream lock before core completes the position rebase,
> and appl_ptr is updated in a separate post_action. Period processing can
> observe the intermediate state.
> 
> Add an optional reset operation whose stream lock remains held through
> the core position and appl_ptr updates. Export the common pointer reset
> as snd_pcm_lib_reset(), so drivers can reuse pointer validation, time
> accounting and XRUN handling without reacquiring the stream lock.
> Drivers without the new operation keep their existing ioctl path.
> 
> A successful callback member completes its reset immediately. If a later
> linked member fails, the first error is returned and completed members
> are not rolled back. Legacy members retain the existing post_action
> [ ... ]
> a user-visible failure. The new-candidate tests validate the
> synchronization contract and recovery paths.
> 
> Assisted-by: LLM
> Signed-off-by: Joonho Lee <[email protected]>

Sashiko has reviewed this patch and found no issues.

-- 
Sashiko AI review ยท 
https://sashiko.dev/#/patchset/[email protected]?part=12


Reply via email to