On Saturday, November 12, 2016 at 9:08:24 AM UTC-5, Radar wrote: > > here is it running by its self using > PYTHONPATH=. python user/interceptor.py --debug --mode=sniff --iface=p5p1 > --filter="src host 192.168.2.14 && dst port 80" --device=acurite-bridge > > raw data: > dateutc=now&action=updateraw&realtime=1&id=24C86E01765D&mt=tower&sensor=00007411&humidity=51&tempf=52.1&baromin=28.67&battery=normal&rssi=2 > raw packet: {'usUnits.00007411.24C86E01765D': 1, > 'barometer.00007411.24C86E01765D': 28.67, > 'temperature.00007411.24C86E01765D': 52.1, > 'bridge_id.00007411.24C86E01765D': '24C86E01765D', > 'humidity.00007411.24C86E01765D': 51.0, 'dateTime': 1478958489, > 'rssi.00007411.24C86E01765D': 50.0, 'sensor_id.00007411.24C86E01765D': > '00007411', 'battery.00007411.24C86E01765D': 0, > 'dateTime.00007411.24C86E01765D': 1478958489, > 'sensor_type.00007411.24C86E01765D': 'tower', 'usUnits': 1} > mapped packet: {'barometer': 28.67, 'txBatteryStatus': 0, 'outHumidity': > 51.0, 'dateTime': 1478958489, 'outTemp': 52.1, 'rxCheckPercent': 50.0, > 'usUnits': 1} > identifiers: {'bridge_id': '24C86E01765D', 'sensor_type': 'tower', > 'sensor_id': '00006045'} >
you're not getting debug log messages, even though you specified --debug. is your syslog configuration hiding debug? m -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. For more options, visit https://groups.google.com/d/optout.