Does the wm300 show values for windchill and heat index? weewx software generated values require temp < 50F and wind > 5mph for windchill and >80F and humidity > 40% for heatindex otherwise will default to the same as outdoor temperature.
On Sunday, 26 February 2017 22:01:41 UTC+2, Miguel Iniesta wrote: > Station: WMR300 > weewx v3.6.2 > > Since updated to v3.6.2, I have realised that windchill/heatindex data are > not available in my system. > In weewx.conf the default option for these data is prefer_harware so I > understand that even a station problem would not prevent these data to be > recorded. > I do not have remote access to my system right now but I do not remember > having modified the value of these parameters. > > Some help would be much appreciated. > Thank you. > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. For more options, visit https://groups.google.com/d/optout.