Hello Amine,

Have you taken a closer look at the band structure of the GGA and mBJ results?

If you get the gap out of the scf files, depending on your k-mesh sometimes you can miss some data.

For instance if you use a k-mesh that does not include the gamma point and there is a sharp cross over at the gamma point. Either way the band structure should give a closer hint as to what is happening.

Regards,

Michael Sluydts


Op 13/09/2013 10:19, Amine Slassi schreef:
Hi,

I tried using mbj , I have running the calculation of materials pure ( supercell 2*2*2) I found that the gap is Eg = 3 eV, and as I made doping of this materails the gap is become Eg = -99.99 eV ( metalic) , (note that with only GGA I don't found this problem. just with MBJ)


Cordially