We have a tower with a single radio operating on it.  We were using a
Microtik 133 board with a single Prizim chipset in it.  One day it
stopped responding to requests through the network using Winbox.  No
customers were down so we assumed it was running bandwidth (too much
snow to travel up there).  One night about 7 PM we started getting tower
down calls, of course we hadn't been able to ping or get into it for
weeks so we had no idea.

Took a back-up 433AH board up and used the same radio card, worked like
a charm for both our access and customer throughput.  We didn't want to
waste a three port/LAN board so ordered a 433a single port board.  Once
it arrived we logged into it by MAC in the office with no problem,
programmed it and sent it up to the tower.  Once on the tower customers
associated just fine but once again we couldn't access the management
side.  We saw the MAC and the identity for it but we couldn't ping that
IP (yes, the 433AH radio was unplugged) and trying to load by MAC would
start the RouterOS download but at various places it would crash.

Moved the 433A down to the hut and a laptop easily logged into it, even
when plugged into the switch, but we still couldn't log into it from
remote, although the laptop on scene was going through the same switch
and by MAC just like we were trying, sigh.  OK we put the 433AH back in
service and again everything worked great.  I'm stumped, we isolated the
switch, Cat 5, and IP Address but those two single cards won't allow us
to log in over using Winbox either by IP or by MAC while it allows it
locally.   *banging head against the wall.  Any ideas?