If the one CPE has this problem and other CPEs off the same AP do not, simply replace the CPE that has problems first.
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Wed, Oct 26, 2016 at 5:24 PM, Mitch <[email protected]> wrote: > Jan > > Give em a call and I will try to help trouble shoot > > Mitch Koep > > 218-851-8689 cell > > > On 10/26/2016 03:26 PM, OOLLC-Support wrote: > > am having an issue with a few nanobeam m2 (little moon shaped things). > > As looked at on the main tab the TX/RX goes to 1/130 Mbs and sticks > > there, customer calls and complains about no internet. Have to power > > cycle it to get it working again. All other CPEs off same tower working > > fine which are mostly nanostation or airgrid models. Upgrade to 5.6.9 > > does not help. > > > > _______________________________________________ > Wireless mailing list > [email protected] > http://lists.wispa.org/mailman/listinfo/wireless >
_______________________________________________ Wireless mailing list [email protected] http://lists.wispa.org/mailman/listinfo/wireless