If the one CPE has this problem and other CPEs off the same AP do not,
simply replace the CPE that has problems first.


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Wed, Oct 26, 2016 at 5:24 PM, Mitch <[email protected]> wrote:

> Jan
>
> Give em a call and I will try to help trouble shoot
>
> Mitch Koep
>
> 218-851-8689 cell
>
>
> On 10/26/2016 03:26 PM, OOLLC-Support wrote:
> > am having an issue with a few nanobeam m2 (little moon shaped things).
> > As looked at on the main tab the TX/RX goes to 1/130 Mbs and sticks
> > there, customer calls and complains about no internet. Have to power
> > cycle it to get it working again.  All other CPEs off same tower working
> > fine which are mostly nanostation or airgrid models.  Upgrade to 5.6.9
> > does not help.
> >
>