I just experienced this behavior playing around tonight, I noticed I got stuck 
in message 2 during a qso and when I hit "Halt TX" it switched off my 
transmitter but did not clear EnableTX button.  Then a few moments later my 
transmitter keyed as it began the next scheduled TX cycle.

I just tried to reproduce (Linux) and I can reproduce it starting up the 
application, enable TX, let it start calling CQ and part way thru hit Halt TX 
while it is transmitting.  The transmitter shuts down but it resumes the next 
scheduled slot.
Also I notice if its not transmitting but is during a "slot" when it should be, 
if I press halt my transmitter seems to quickly key up then un-key immediately.
If I press Halt TX during a slot when I am not supposed to be transmitting, 
nothing happens.

I'm using an ICOM 7100 with CAT control if that makes any difference for the 
PTT selection.

-Matt / KK4NDE

-----Original Message-----
From: Bill Somerville [mailto:g4...@classdesign.com] 
Sent: Tuesday, April 30, 2019 12:00 PM
To: wsjt-devel@lists.sourceforge.net
Subject: Re: [wsjt-devel] Halt Tx Button

On 30/04/2019 02:10, Neil Zampella wrote:
> Hi all,
>
> trying to stop a Tx by clicking the Halt Tx button, it stopped the 
> rig, but did NOT reset the Enable Tx, and actually caused a couple of 
> entries in the RxFrequency window when I clicked it twice.
>
> Tested it under FT8 mode, and it works normally there. V2.1.0-RC5 64 bit.
>
> Neil, KN3ILZ

Hi Neil,

thanks for the issue report. I am unable to reproduce this, if you can come up 
with a recipe for reproduction that would be most helpful.

73
Bill
G4WJS.



_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel


_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to