I have it working again but I don't understand why.

I uninstalled two recent windows 8.1 updates - made no difference.

I made a fresh installation of WSJT-X 2.3.0 in a new directory.  it would not 
connect to Omni-Rig

I started WSJT-X ver 1.9.1 from its BIN directory and it connected to Omni-Rig.

I started WSJT-X ver 2.3.0 from its BIN directory and it connected to Omni-Rig

I started the original version of WSJT_X ver 2.3.0 via a shortcut to the 
original 2.3.0 installation directory.  It connected ok.

I started WSJ-X ver 2.5.4 from a shortcut to its installation directory and it 
connect ok.

I don't know what caused the problem and I don't know why it went away.  The 
only thing I know was changed between WSJT-X not connecting to Omni-Rig and it 
connecting to Omni-Rig was that I ran WSJT-X ver 1.9.1.  (I usually install 
each version in a separate directory and have lots of old versions available to 
run).

Andy, k3wyc


________________________________
From: Andy Durbin <a.dur...@msn.com>
Sent: Saturday, November 26, 2022 12:19 PM
To: Uwe, DG2YCB <dg2...@gmx.de>; WSJT software development 
<wsjt-devel@lists.sourceforge.net>
Subject: Re: [wsjt-devel] Help with Omni-Rig

Uwe,

Thanks for your reply.

OmiRig is installed at C:\Program Files (x86)\Afreet\OmniRig.  I can run it 
from there my clicking the exe or I can run it with the client, or I run it 
from HDSDR or CW Skimmer.  I just can't run it from any version of WSJT-X.

All versions of WSJT-X used to open Omni-RIg but now they don't.  The only 
thing I know I did between it working and it not working is to update N1MM.  
Unfortunately I don't have a good restore point  as they have all been deleted.

I have tried uninstalling OmniRig and installing again from an archived copy of 
1.19 but that changed nothing.  When I uninstalled OmniRig I also deleted the 
C:\Program Files (x86)\Afreet\OmniRig directory.  OmniRig still opens using a 
custom rig definition that is not included in the rig directory of C:\Program 
Files (x86)\Afreet\OmniRig.  I don't know how it finds that rig definition.

I see no hung processes in task manager.  I'm running Windows Defender and I 
see no recent removed or quarantined items in history.

If no other app could connect to Omni-Rig then I'd assume it was an Omni-Rig 
installation problem but other apps do connect to it.

73,
Andy, k3wyc
________________________________
From: Uwe, DG2YCB <dg2...@gmx.de>
Sent: Saturday, November 26, 2022 11:27 AM
To: WSJT software development <wsjt-devel@lists.sourceforge.net>
Cc: Andy Durbin <a.dur...@msn.com>
Subject: Re: [wsjt-devel] Help with Omni-Rig


Hi Andy,


WSJT-X gets the path to OmniRig from Windows. No settings are required for this 
within WSJT-X. Usually, OmniRig installs into "C:\Program Files 
(x86)\Afreet\OmniRig" but the only thing that matters is which path is stored 
in the registry, and whether this path is correct. Please check if your 
firewall or your virus scanner block somehow the communication between WSJT-X 
and OmniRig. And see if there is a hanging process somewhere (wsjtx.exe, 
jt9.exe or omnirig.exe). I am using OmniRig myself. It works here very well 
with my Yaesu FT-991 and numerous WSJT-X versions. I am currently using 1.20, 
but 1.18 or 1.19 work as well. Yesterday or the day before, I noticed that some 
Windows update seemed to briefly interfere with the connection to OmniRig. But 
that has since resolved itself for me.

73 de DG2YCB,
Uwe
________________________________________
German Amateur Radio Station DG2YCB
Dr. Uwe Risse
eMail: dg2...@gmx.de<mailto:dg2...@gmx.de>
Info: www.qrz.com/db/DG2YCB<http://www.qrz.com/db/DG2YCB>


Am 26.11.2022 um 17:56 schrieb Andy Durbin via wsjt-devel:
I have been running various versions of WSJ-X with Omni-Rig for many years.  
After having my station shut down for about a week I can no longer run WSJT-X 
with Omni-Rig.  Error "Failed to start OmniRig COM server".

If I run Omni-Rig client it connects to my TS-590S with no issue.  If I close 
Omni-Rig client and open HDSDR or CW Skimmer both connect to Omni-Rig and 
establish 2 way communication with my TS-590S.

It's clear that Omni-Rig and the client are working but it appears that WSJT-X 
either cannot find Omni-Rig client or is unable to start it.

Where does WSJT-X expect to find Omni-Rig client and where is the path 
specified?

I have found several discussions of this problem but have not found a solution. 
 WSJT-X installation was not intentionally changed and I see the same problem 
with ver 2.3.0, ver 2.5.4, and 2.6.0 rc4.  All these versions used to connect 
to Omni-Rig until this new problem started.

I changed WSJT-X to start with admin privilege and have the same error.  I also 
see the same with Omni-Rig 1.19 and 1.20.  Omni-Rig client seems to have been 
unchanged since 2004.

Any ideas on how to fix this?

Thanks and 73,
Andy k3wyc




_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net<mailto:wsjt-devel@lists.sourceforge.net>
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to