Marco Jackel wrote:
Hi,
Philippe Gerum wrote:
Marco Jackel wrote:
"rt_dev_read" gives negative Results. Whats wrong?
Which negative code is returned exactely?
It returns -5
-EIO. Except for traditional RTOS skins like VxWorks, VRTX and so on
which have their own error list, we tend to normalize on POSIX error
codes in all other parts of the codebase.
Regarding the EIO issue, it looks like a transmission error has been
detected on the read-side by the 16650A driver. Jan will likely tell you
more when time allows.
Are the error-codes documented somewehere?
Yes, the documentation link on our website is a good starting point. For
the particular EIO issue on the serial driver, I'm not sure there is a
lot more explanations than the one above, though.
Thanks
Maggo
_______________________________________________
Xenomai-help mailing list
[email protected]
https://mail.gna.org/listinfo/xenomai-help
--
Philippe.
_______________________________________________
Xenomai-help mailing list
[email protected]
https://mail.gna.org/listinfo/xenomai-help