On 09.07.19 18:21, Lange Norbert wrote: > Hello, > > maxcpus=1 still causes the spurious int, this time fully locking up. > > I attached the debug/irq directory after the cause. > > Some things that might be relevant: > - the SOC would use PINCTRL_BROXTON under linux, but this is disabled (not > fixed up for Xenomai) > - I have the regular igb driver in use, and am unbinding the network card > prior to binding the rt_igp driver >
Thanks. What's the interrupt number that Xenomai is using? Should be the same that the Linux driver is using as well. Jan -- Siemens AG, Corporate Technology, CT RDA IOT SES-DE Corporate Competence Center Embedded Linux