On 09.07.19 18:21, Lange Norbert wrote:
> Hello,
> 
> maxcpus=1 still causes the spurious int, this time fully locking up.
> 
> I attached the debug/irq directory after the cause.
> > Some things that might be relevant:
> -   the SOC would use PINCTRL_BROXTON under linux, but this is disabled (not 
> fixed up for Xenomai)
> -   I have the regular igb driver in use, and am unbinding the network card 
> prior to binding the rt_igp driver
> 

Thanks. What's the interrupt number that Xenomai is using? Should be the same
that the Linux driver is using as well.

Jan

-- 