Hi,
One of my drives failed in Raidz2 with two hot spares:
# zpool status
pool: fwgpool0
state: DEGRADED
status: One or more devices could not be opened. Sufficient replicas
exist for
the pool to continue functioning in a degraded state.
action: Attach the missing device and online it using 'zpool online'.
see: http://www.sun.com/msg/ZFS-8000-2Q
scrub: resilver completed after 0h0m with 0 errors on Mon Apr 25
14:45:44 2011
config:
NAME STATE READ WRITE CKSUM
fwgpool0 DEGRADED 0 0 0
raidz2 DEGRADED 0 0 0
c4t5000C500108B406Ad0 ONLINE 0 0 0
c4t5000C50010F436E2d0 ONLINE 0 0 0
c4t5000C50011215B6Ed0 ONLINE 0 0 0
c4t5000C50011234715d0 ONLINE 0 0 0
c4t5000C50011252B4Ad0 ONLINE 0 0 0
c4t5000C500112749EDd0 ONLINE 0 0 0
c4t5000C5001128FE4Dd0 UNAVAIL 0 0 0 cannot open
c4t5000C500112C4959d0 ONLINE 0 0 0
c4t5000C50011318199d0 ONLINE 0 0 0
c4t5000C500113C0E9Dd0 ONLINE 0 0 0
c4t5000C500113D0229d0 ONLINE 0 0 0
c4t5000C500113E97B8d0 ONLINE 0 0 0
c4t5000C50014D065A9d0 ONLINE 0 0 0
c4t5000C50014D0B3B9d0 ONLINE 0 0 0
c4t5000C50014D55DEFd0 ONLINE 0 0 0
c4t5000C50014D642B7d0 ONLINE 0 0 0
c4t5000C50014D64521d0 ONLINE 0 0 0
c4t5000C50014D69C14d0 ONLINE 0 0 0
c4t5000C50014D6B2CFd0 ONLINE 0 0 0
c4t5000C50014D6C6D7d0 ONLINE 0 0 0
c4t5000C50014D6D486d0 ONLINE 0 0 0
c4t5000C50014D6D77Fd0 ONLINE 0 0 0
spares
c4t5000C50014D70072d0 AVAIL
c4t5000C50014D7058Dd0 AVAIL
errors: No known data errors
I'd expect the spare drives to auto-replace the failed one but this is
not happening.
What am I missing?
I really would like to get the pool back in a healthy state using the
spare drives before trying to identify which one is the failed drive in
the storage array and trying to replace it. How do I do this?
Thanks for any hints.
--
Peter
_______________________________________________
zfs-discuss mailing list
zfs-discuss@opensolaris.org