Re: [PSES] DoC - reference to ROHS directive

2024-04-26 Thread Matthew Wilson | GBE
In our experience purchasers/compliance officers in large retail organisations expect to explicitly see the RoHS amendment listed in the DoC text as per Mike writes below, because this ticks their box that the product has addressed the additional four substances the amendment was concerned

Re: [PSES] UKCA Extension .... again

2024-01-25 Thread Matthew Wilson | GBE
To further this thread - The UK Government yesterday (24th January) announced an additional, non-mandatory 'Fast Track UKCA Process' for products placed on the GB market. See the 'banner' grey box area added to the top of this gov.uk URL link below. At a later date the page will get further

[PSES] UK extends CE mark recognition indefinitely

2023-08-01 Thread Matthew Wilson | GBE
https://www.gov.uk/guidance/ukca-marking-conformity-assessment-and-documentation Reporting: https://www.theguardian.com/politics/2023/aug/01/uk-eu-safety-mark-brexit-climbdown - the funny bit here is that the original article was accompanied by a picture of a non-compliant CE logo, as per the

[PSES] BBC news article re Li-ion batteries...

2023-07-28 Thread Matthew Wilson | GBE
I thought this news article that was on the BBC TV broadcast bulletins 27th July might be of interest. "Batteries for e-bikes should be regulated in the same way as fireworks, heavy machinery or medical devices because of the fire risk they pose, a charity [UK based Electrical Safety First]

Re: [PSES] EU CE Marking Exemptions for Military Equipment Query

2021-10-22 Thread Matthew Wilson | GBE
It's old now but this article, written by someone working for TUV SUD, was handy for me when needing to deal with the 'military exempt argument' a while ago. https://www.newelectronics.co.uk/electronics-technology/the-military-ce-marking-conundrum/64803/ It agrees with your stance, which I

Re: [PSES] Will 5G Be Bad for Our Health?

2021-10-18 Thread Matthew Wilson | GBE
I don't think this issue regards radio spectrum use will ever get resolved ever. Why - well explained rather neatly by Ben Goldache's answer to, "How many epidemiologists does it take to change a lightbulb?" We've found 12,000 switches hidden around the house. Some of them turn this

Re: [PSES] Non-isolated Solar Invertor EMC emissions

2021-10-14 Thread Matthew Wilson | GBE
> Matthew Wilson Technical Director GB Electronics (UK) Ltd matthew.wil...@gbelectronics.com https://gbelectronics.uk +44 (0)1903 244 500 Ascot House//Mulberry Close//Woods Way Goring-by-Sea//West Sussex//BN12 4QY//UK Disclaimer: This email and any files transmitted with it are confidential and

[PSES] U.S. equivalent to BS 1363...

2021-09-07 Thread Matthew Wilson | GBE
Hello all, unfortunately I'm not too familiar with U.S. standards. I am looking for the equivalent information of BS 1363-1 that would describe the standard U.S. mains plug and socket dimensions, plug pin lengths, spacings etc. I nice 2D dimensioned drawing would be ideal. The reason is we

[PSES] UK CE mark extension...

2021-08-24 Thread Matthew Wilson | GBE
For those involved in UKCA Marking, note that the UK's decision to accept CE Marking on equipment put on the market in Great Britain has been extended by a year. An extra year of transition period now exists. The UK will allow CE Marked equipment into Great Britain until 1 January 2023

Re: [PSES] Multiple Power cord-sets bundled with product Redux UK Plugs BS 1363 as the standard plug

2021-08-23 Thread Matthew Wilson | GBE
Good read and resource that thank you. https://xkcd.com/927/ comes to mind :-) Matthew Wilson, GB Electronics (UK) Ltd. Matthew Wilson Technical Director GB Electronics (UK) Ltd matthew.wil...@gbelectronics.com https://gbelectronics.uk +44 (0)1903 244 500 Ascot House//Mulberry Close//Woods Way

Re: [PSES] Basic Schematic Creation Software

2021-05-22 Thread Matthew Wilson | GBE
The Draw component of Libre Office https://www.libreoffice.org/ has symbol extensions for schematics here https://sschmidhuber.github.io/LibreSymbols/ Draw lets you make rubber band connections between elements, handy for reorganising a drawing as it is made without having to redraw all the

Re: [PSES] ECE R10 - Addendum 9 - rev. 6 / Applicability of this regulation for ESA type of equipment with a particular 'interface type"

2021-03-12 Thread Matthew Wilson | GBE
https://ec.europa.eu/docsroom/documents/16513/attachments/1/translations/en/renditions/native Category C in the table is if you have determined that the ESA is involved, as per UNECE Regulation 10.5 Section 2.12, with immunity related functions, i.e. one of affecting the direct control of the

[PSES] Instruction for use symbol...

2021-02-05 Thread Matthew Wilson | GBE
I was asked what symbol should be used on a piece of equipment, where the EN 61010-1 safety standard applies, to denote 'read the instructions for use'? Prior just some English wording was used but a symbol would be better as the equipment may be used within the EU. It is not clear to me

[PSES] Energy efficiency for power supplies...

2021-01-21 Thread Matthew Wilson | GBE
EU 2019/1782 is the ecodesign requirements for external power supplies, i.e. their efficiency, for Directive 2009/125/EC. Someone asked me how the formula in 1(b) of Annex II of the EU 2019/1782 regulation was decided upon. This table sets out the determination of 'average active efficiency'.

[PSES] Industrial PSU to Australia...

2020-02-21 Thread Matthew Wilson | GBE
Hello all, I've had an enquiry for a product we produce from Australia from an entity (not individual) down under. The product in question is an 'industrial' power supply unit, 230V 50Hz AC in, 115V 400Hz out up to 3kW. It is self-declared CE mark for EMC & LVD (EN 61326-1 and EN 61010-1) plus

Re: [PSES] CISPR 25 Limits for conducted disturbances - guidance for selecting emissions class

2020-02-07 Thread Matthew Wilson | GBE
Maybe some document like this from Ford would help? https://www.elect-spec.com/download/EMC_CS_2009rev1.pdf Similar from Jaguar Land Rover? http://emc.jaguarlandrover.com.edgesuite.net/docs/download/JLR-EMC-CS_v1.0_Amendment_4.pdf Have a look for "Automotive OEM Specifications" on your chosen

Re: [PSES] ErP 2009/125/EC

2020-02-07 Thread Matthew Wilson | GBE
>From something I wrote as an internal memo to my design team a little while >ago regards selecting PSU units for equipment to be placed on the market in >the EU and UK. (The U.S. requires VI anyway I believe, source - >https://www.cui.com/efficiency-standards ) What is VI 2020? In

Re: [PSES] AC net filter - Conducted emission - differential mode

2020-02-01 Thread Matthew Wilson | GBE
Could look at the offerings from Wurth Würth Elektronik, and/or contact your local Würth Elektronik office. We have found them helpful when it comes to sourcing components for EMC purposes. https://www.we-online.com/catalog/en/WE-CLFS/ Matthew Wilson, GB Electronics (UK) Ltd. > Matthew Wilson

Re: [PSES] CE marking quality manufacturing requirements

2020-01-15 Thread Matthew Wilson | GBE
Look at https://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2008:218:0082:0128:en:PDF This is, “DECISION No 768/2008/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 9 July 2008 on a common framework for the marketing of products” See Annex II Module A1 and Module A2 in that

[PSES] BBC report...

2019-11-20 Thread Matthew Wilson | GBE
This was on the BBC News website today: Amazon and eBay criticised for 'unsafe toys' - https://www.bbc.co.uk/news/business-50478221 Matthew Wilson Technical Director GB Electronics (UK) Ltd matthew.wil...@gbelectronics.com https://gbelectronics.uk +44 (0)1903 244 500 Ascot House//Mulberry

[PSES] EU PSU efficiency...

2019-11-11 Thread Matthew Wilson | GBE
I haven't seen much press about the changes to external power supply energy efficiency ratings in the EU and UK that has appeared on the EU and UK .gov websites - "Commission Regulation (EU) 2019/1782 of 1 October 2019 laying down ecodesign requirements for external power supplies pursuant to

Re: [PSES] Fuse in device is mandatory or not?

2019-11-01 Thread Matthew Wilson | GBE
If you are considering a fuse you may need to consider using two on both 'live' and 'neutral' with a suitable warning. This is due to 'EU' mains plug connectors being un-polarised. So the mains plug can be inserted either way around, allowing the live and neutral to the appliance to be

Re: [PSES] Power supply 60335 or 60950...

2019-10-24 Thread Matthew Wilson | GBE
Thank you all for your replies, much appreciated. I do offer apologies for the use of ‘jack plug’ and ‘jack socket’ which of course suggests a non-suitable connector akin to ‘headphone jack’. Quite righty as pointed out not a good idea at all. I remember a long time ago wrecking a Sinclair

[PSES] Power supply 60335 or 60950...

2019-10-24 Thread Matthew Wilson | GBE
A client has a product, to be used by consumers typically in a bedroom or child's nursery, which has a microcontroller and is Wi-Fi enabled so it can present data to 'the cloud' and interact with a mobile phone 'app' to change some parameters on the device. We have been asked by the client

[PSES] Product Declaration of Conformity with external PSU...

2019-04-10 Thread Matthew Wilson | GBE
A consumer product is powered by AA cells but also can derive its power from a 'wall wart' mains-DC PSU via a DC jack input on the product. The client who is the manufacturer of the product (as per the EU directive) has decided to supply a third-party wall-wart PSU in the box with the product.