If the FS is tough enough to run from the NID to the biscuit and withstand 
staples, tight bends and UV then it sounds pretty good.  But I really like the 
little metal bullet end on the pre terminated Miniflex.  Easy to push through a 
wall etc.  

From: Carl Peterson 
Sent: Thursday, August 13, 2020 11:34 AM
To: AnimalFarm Microwave Users Group 
Subject: Re: [AFMUG] CPE Install Costs.xlsx

FS armored patch is different then clearfield pushable.  FS has a 900um loose 
inside a metal spiral with a PVC jacket.  CFD pushable has a 900um in gel 
inside a thick plastic jacket.  You can't really push the FS with connectors on 
it, or at all really.  The FS is much more flexible and doesn't kink like CFD 
pushable but you can't push it.  I don't like CFD pushable outside of 
microduct.  Too easy to mess up and there are better fibers for the 
application.  



On Thu, Aug 13, 2020 at 10:56 AM Mark Radabaugh <m...@amplex.net> wrote:

  Well,   I have managed to put a staple through it if that counts :-)   If you 
don’t shoot the staple right through it it works fine - I just had bad aim.   
And for what it’s worth the cable still worked.   It’s at my house so I’m not 
too worried about it.  Hopefully our install crew uses a little more care. 

  It’s relatively stiff but it’s not like the Clearfield or other brands of 
pushable fiber that have a very minimal diameter protected stub at the end that 
you then assemble the SC connector to after pushing it in.   You can get the 
movable part of the SC connector to pop off but you still have the full square 
end of the SC to deal with - it won’t go through most microduct, but you can 
get it through the normal drill size you shove CAT-5 cable though.

  Mark



    On Aug 13, 2020, at 11:22 AM, ch...@wbmfg.com wrote:

    Will this FS stuff take a staple and can you push it through microduct?

    From: Mark Radabaugh 
    Sent: Wednesday, August 12, 2020 7:23 PM
    To: AnimalFarm Microwave Users Group 
    Subject: Re: [AFMUG] CPE Install Costs.xlsx

    I fhink you preterminated indoor jumper cost is too high.   These 
https://www.fs.com/c/armored-patch-cables-220 work fine for the inside wiring 
from the outdoor box to the wall plate or direct to CPE if you are not doing a 
inside jack.  They are not UV rated so you have to make sure you don’t leave 
them exposed outdoor.   You can pop the outer SC portion off the jumper if you 
want to pass through a smaller hole. 

    Mark



      On Aug 12, 2020, at 7:00 PM, ch...@wbmfg.com wrote:

      <CPE Install Costs.xlsx>



----------------------------------------------------------------------------
    -- 
    AF mailing list
    AF@af.afmug.com
    http://af.afmug.com/mailman/listinfo/af_af.afmug.com

    -- 
    AF mailing list
    AF@af.afmug.com
    http://af.afmug.com/mailman/listinfo/af_af.afmug.com


  -- 
  AF mailing list
  AF@af.afmug.com
  http://af.afmug.com/mailman/listinfo/af_af.afmug.com



-- 

Carl Peterson


PORT NETWORKS

401 E Pratt St, Ste 2553

Baltimore, MD 21202

(410) 637-3707 



--------------------------------------------------------------------------------
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to