I can't shorten the cable, but I can increase the wire size to 23 awg Cat6
and increase the amperage available to 1 amp.


On Sun, Apr 18, 2021 at 8:28 PM TJ Trout <t...@voltbb.com> wrote:

> This is something that can be easily calculated;
>
> 450b 10w @ 24v
>
> Cable 24awg @ 200ft
>
> Voltage drop: 2.14
> Voltage drop percentage: 8.90%
> Voltage at the end: 21.86
>
> Input Voltage 20 - 32 V DC
>
> Probably need to shorten the cable or increase the wire size or increase
> the supply voltage..
>
> On Sun, Apr 18, 2021, 6:13 PM Sam Lambie <samtaos...@gmail.com> wrote:
>
>> Hey all,
>>
>> I am running into some issues with a 450b PTP setup. The Slave is running
>> at 200' of cable and the radio powers up, but doesn't transmit. I got it to
>> talk to the BHM (450b) and toned in the signal at -58 on both ends for a
>> couple of days at one point then it fizzled out. Swapped channel and
>> frequencies, No connection. Spectrum scan on both sides shows a totally
>> clean channel in many spots, and I have tried them all. I swapped out the
>> radio and the same thing happened. So... I am thinking it's voltage drop
>> with the dinky 0.5 amp PSU.
>> Does anyone make one that is 1-1.5 amps at 30vdc?
>> I am going to take a 24vdc 1 amp power supply from a Ubiquiti radio and
>> swap pairs on the Ethernet cable to see if I can get it to work and prove
>> my theory.
>> Has anyone ran into this situation?
>>
>> thanks,
>>
>> --
>> --
>> *Sam Lambie*
>> Taosnet Wireless Tech.
>> 575-758-7598 Office
>> www.Taosnet.com <http://www.newmex.com>
>> --
>> AF mailing list
>> AF@af.afmug.com
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>


-- 
-- 
*Sam Lambie*
Taosnet Wireless Tech.
575-758-7598 Office
www.Taosnet.com <http://www.newmex.com>
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com